Danfoss iC7 Series Operating Manual page 33

Functional extension options
Hide thumbs Also See for iC7 Series:
Table of Contents

Advertisement

Functional Extension Options
Operating Guide
17
15
9
7
3
5
2
1
18
16
14
12
10
8
6
4
13
11
Illustration 20: Wiring Configuration for HIPERFACE DSL® and Incremental (TTL or HTL) Encoder
1
Incremental encoder
2
External power supply
5.5.15 BiSS Encoder
Absolute position is read from the encoder and used to set the actual position after power-up.
Table 22: Parameters for BiSS Encoder
Parameter
9.4.1 Interface configuration
9.4.4 Encoder Supply Voltage
9.6.1 Singleturn Resolution
9.6.2 Multiturn Resolution
9.6.5 BiSS/SSI Clock Rate
Danfoss A/S © 2023.06
A+
A–
B+
B–
Setting
Select [29] BiSS Z,D.
Set the appropriate supply voltage.
Voltage can be up to 24 V. Setting the voltage too high can damage the connected encoder.
Set the number of bits used for 1 revolution.
Set the number of bits used for revolution count.
Set the rate for the clock signal according to the encoder specifications.
1
2
Data/supply+
Data/supply–
3
HIPERFACE DSL® encoder
N O T I C E
Encoder/Resolver Installation and
Configuration
3
AQ390830267692en-000601 / 136R0273 | 33