Danfoss iC7 Series Operating Manual page 39

Functional extension options
Hide thumbs Also See for iC7 Series:
Table of Contents

Advertisement

Functional Extension Options
Operating Guide
Selection number
7
8
9
10
17
19
33
34
22
23
25
26
27
29
30
31
32
P 9.4.2 Encoder Supply Voltage
Description: Set the supply voltage level according to the specifications of the connected encoder.
Default Value : 5
Unit: V
P 9.4.3 Supply Sense
Description: Enable power supply cable drop compensation.
Default Value : 0 [Disabled]
Unit: -
The following are the selections for the parameter.
Selection number
0
1
P 9.4.4 Invert Direction Channel 1
Description: Select if signal on channel 1 shall be inverted. For dual output channel encoders this parameter affects the entire en-
coder information (absolute and incremental part).
Default Value : 0 [Disabled]
Unit: -
Danfoss A/S © 2023.06
Selection name
Resolver A,B
Resolver A,B + mirror out Z,D
Resolver A,B + 2 track incremental Z,D
SinCos A,B
SSI Z,D
SSI Z,D + 2 track incremental A,B
SSI with 2 track incremental Z,D,A,B
SSI with SinCos Z,D,A,B
EnDat Z,D
EnDat Z,D + 2 track incremental A,B
HIPERFACE A,B,D
HIPERFACE DSL D
HIPERFACE DSL D + 2 track incremental A,B
BiSS Z,D
BiSS Z,D + 2 track incremental A,B
BiSS with 2 track incremental Z,D,A,B
BiSS with SinCos Z,D,A,B
Parameter Type: Range (3 — 24)
Data Type: UINT
Parameter Type: Selection
Data Type: BOOL
Parameter Type: Selection
Data Type: BOOL
Encoder/Resolver Installation and
Parameter Number: 4002
Access Type: Read/Write
Parameter Number: 4035
Access Type: Read/Write
Selection name
Disabled
Enabled
Parameter Number: 4092
Access Type: Read/Write
AQ390830267692en-000601 / 136R0273 | 39