Functional Extension Options
Operating Guide
17
15
9
7
3
5
2
1
18
16
14
12
10
8
6
4
13
11
Illustration 10: Wiring Configuration for Resolver with Mirror Out
1
Resolver
2
Controller or other device
5.5.5 Resolver and Incremental (TTL) Encoder
This example of a resolver on A and B as channel 1 and a 2-track incremental TTL encoder on Z and D as channel 2. The internal
supply of the option is used for resolver excitation. The encoder supply (pin 17) is inactive, so the incremental encoder must be
supplied by an external power source.
Table 12: Parameters for Resolver and Incremental (TTL) Encoder
Parameter
9.4.1 Interface configuration
9.5.2 Resolution Channel 2
9.7.1 Excitation Voltage
9.7.2 Excitation Frequency
9.7.3 Number of Pole Pairs
Danfoss A/S © 2023.06
Ref+
Ref–
1
Sin+
Sin–
Cos+
Cos–
Setting
Select [9] Resolver A,B + 2 track incremental Z,D.
Set the resolution of the encoder connected to Z and D in pulses per revolution.
Set the excitation voltage according to the resolver specifications.
Set the resolver excitation frequency according to the resolver specifications.
Set the number of pole pairs for the connected resolver.