Temperature Compensation (P660 To P664) - Siemens airanger DPL PLUS Instruction Manual

Table of Contents

Advertisement

P653 Velocity
The value adjusted based on the Sound Velocity at 20 °C (P654) vs. Temperature (P664)
characteristics of air.
Primary Index
Values
Related
Alternatively, enter the current sound velocity (if known), or perform a Sound Velocity
Calibration (P651). The units used are m/s if P005 = 1, 2, or 3 or ft/s if P005 = 4 or 5.
P654 Velocity at 20°C
This value is used to automatically calculate Sound Velocity (P653).
Primary Index
Values
Related
After performing a Sound Velocity Calibration, check this value to verify the acoustic
beam atmosphere is air (344. 1 m/s or 1129 ft/s).
Alternatively, if the acoustic beam atmosphere sound velocity at 20°C (68 °F) is known,
and the sound velocity vs. temperature characteristics are similar to that of air, enter the
sound velocity.
The units used are m/s if P005 = 1, 2, or 3 or ft/s if P005 = 4 or 5.

Temperature Compensation (P660 to P664)

P660 Temp Source
Source of the temperature reading used to adjust the speed of sound.
Primary Index
Values
Alters
Related
Page 60
Transducer
Range: 50.01 to 2001 m/s (164.1 to 6563 ft/s)
P651 Sound Velocity Calibration
P654 Velocity at 20°C
Transducer
Range: 50.01 to 2001 m/s (164.1 to 6563 ft/s)
P005 Units
P651 Sound Velocity Calibration
P653 Velocity
Transducer
1
*
AUTO
2
Temp Fixed
3
Ultrasonic/Temperature Transducer
4
TS-3 Temperature Sensor
5
Average (TS-3 and transducer)
6
TS-3 Sensor #1
P664 Temperature
P651 Sound Velocity
P653 Velocity
P654 Velocity at 20°C
P661 Temp Fixed
AiRanger DPL Plus – INSTRUCTION MANUAL