Mounting

Inspect all cartons and packaging for possible damage during shipment, before removing
the AiRanger DPL Plus and associated equipment.
1.
Loosen the 6 enclosure lid (captivated) screws and swing the lid open.
2.
Remove the 4 Board B mounting screws (outer corners) and remove the circuit
board assembly.
3.
Drill required holes in the enclosure bottom to meet enclosure cable/conduit entry
requirements.
4.
Attach the enclosure to the selected mounting surface (use four predrilled screw
holes).
5.
Attach the conduits/cable hubs to the enclosure. (Do not apply undue force.)
6.
Reinstall the circuit board assembly.
209 mm
1
(8.2")
172 mm
(6.8")
suitable location for conduit entrances.
Use water tight conduit hubs to maintain the enclosure rating.
Warnings
Non metallic enclosure does not provide grounding between connections. Use
grounding type bushings and jumpers.
This product is susceptable to electrostatic shock. Follow proper grounding
procedures.

Transducer Mounting

Objects near the transducer face cannot be reliably detected. Mount the transducer
above the highest material level (away from the nearest monitored object) by the
following Nearest Distance.
Nearest Distance
1
0.5 m (1.65 ft)
0.66 m (2.17 ft)
0.99 m (3.25 ft)
1.32m (4.33 ft)
1.
This is the recommended minimum distance. However, it can be reduced under certain circum-
stances. Please check the appropriate transducer manual for details.
Page 10
285 mm
(11.2")
267 mm
(10.5")
2
3
4
1 2
ST-H, ST-25, XRS-5, XCT-8, XCT-12, XPS-10, XPS-15, ST-50
XPS-30, XPS-40
ST-100, LR-21, XLT-30, XLS-30
LR-13, XLT-60, XLS-60
AiRanger DPL Plus – INSTRUCTION MANUAL
lid screw
(6 places)
1
2
3
4
5
6
7
8
mA
9
0
P
P
X X X
C
programmer
mounting hole, 4.3 mm (0.17")
diameter, access under lid (4 places).
Transducer Types
106 mm
(4.2")
lid (hinged)
customer
mounting screws
7ML19981BD02