Rate (P700 to P707)
These parameters determine how material level changes are reported.
P700 Max Fill Rate
Adjusts the AiRanger DPL Plus response to increases in the actual material level (or
advance to a higher Failsafe Material Level, P071).
Primary Index
Values
Altered by
Related
Enter a value slightly greater than the maximum vessel filling rate. This value, in Units
(P005) or % of Span (P007) per minute, is automatically altered when Maximum Process
Speed (P003) is altered.
P003 Value
1
2
3
P701 Max Empty Rate
Adjusts the AiRanger DPL Plus response to decreases in the actual material level (or
advance to a lower Failsafe Material Level, P071).
Primary Index
Values
Altered by
Related
Enter a value slightly greater than the maximum vessel emptying rate. This value, in Units
(P005) or % of Span (P007) per minute, is automatically altered when Maximum Process
Speed (P003) is altered.
P003 Value
1
2
3
7ML19981BD02
Transducer
Range: 0.000 to 9999
•
P003 Maximum Process Speed
•
P005 Units
•
P007 Span
•
P071 Failsafe Material Level
Transducer
Range: 0.000 to 9999
•
P003 Maximum Process Speed
•
P005 Units
•
P007 Span
•
P071 Failsafe Material Level
Meters / Minute
AiRanger DPL Plus – INSTRUCTION MANUAL
Meters/Minute
0.1
1
10
0.1
1
10
Page 63