When a record is displayed, results are based on current programming (which may have
been altered since the record was saved). This permits the effect on the echo profile to be
observed when changing an echo parameter.
P330 Profile Record
Records profiles for later viewing.
Primary Index
Values
In addition to being a profile records library, this provides two functions:
manually records and saves echo profiles
displays an echo profile, recorded manually or automatically (oscilloscope)
To select a record address
1.
Enter PROGRAM mode and press DISPLAY
The field shows two underscores _ _.
2.
Type the index number. The profile record information is shown.
3.
Use ARROWs
To manually record a profile
Press TRANSDUCER
internal scope buffer for display.
For differential or average operation (P001 = 4 or 5), access Scope Displays (P810)
parameter to select the transducer number.
To save a manual record
Press ENTER
selected address in the record library. The parameter value field displays the new record
information.
To display a record
Press MODE
Then press TRANSDUCER
display on an oscilloscope or Dolphin Plus
To delete a record
Press CLEAR
address. The value returns to - - - -.
Page 54
Echo profile
Code
----
no record
A1
automatically recorded profile from Transducer One
A2
automatically recorded profile from Transducer Two
U1
manually recorded profile from Transducer One
U2
manually recorded profile from Transducer Two
to scroll through the records.
to fire the transducer and record the echo profile into the
to copy the echo profile record in the scope buffer and save it in the
key to enter display auxiliary mode.
to copy the current echo profile into the scope buffer for
and then ENTER
AiRanger DPL Plus – INSTRUCTION MANUAL
Description
twice to highlight the index field.
to delete the echo profile record in the selected
7ML19981BD02