Read Head Orientation; Horizontal Tolerance-Read Distance Z - Pepperl+Fuchs PXV100AQS-F200-R4-V19- 6011 Manual

Data matrix positioning system
Table of Contents

Advertisement

PXV100AQS-F200-R4-V19-6011
Planning
5.6

Read Head Orientation

5.6.1
Horizontal Tolerance—Read Distance z
The read head offers the highest possible depth of field for cornering horizontal curves and
mounting at different reading distances. If the read head is mounted too close or too far away
on the Data Matrix code tape, a warning message is issued. We recommend that the read head
always be mounted at a nominal distance of 100 mm to ensure the highest possible availability
of the system (due to resolution and code redundancy). Pay particular attention to the reduced
mounting tolerance in the y direction and the reduced gap width, especially at extremely close
reading distances.
1
2
Green
Yellow
Red
Read distance
(z)
< -z
mm
0
< 70 mm
100 mm
> 130 mm
> +z
mm
0
y
x
z
0
no pos.
wrn
+z₀
130
Two-colored Data Matrix code tape
Read distance to the Data Matrix code tape in z direction
Recommended reading range: Nominal value 100 mm ± depth of field
Range in which a "warning bit" is set
Range in which a "no pos. bit" is set
Range
"no pos." bit
x
x
wrn
no pos.
100
70
-z₀
Range
"warning" bit
x
x
1
2
0