USE AND MAINTENANCE INSTRUCTIONS MA-
NUAL
TO BE KEPT BY THE USER
1. MANUFACTURER AND ELECTRO-
PUMP IDENTIFICATION DATA
1.1 MANUFACTURER DATA
EBARA PUMPS EUROPE S.p.A.
Head office and factory
Via Pacinotti, 32
36040 BRENDOLA (VI) ITALIA 38023 CLES (TN) ITALIA
Telephone: 0444/706811
Telefax:
0444/706950
Telex:
480536
1.2. ELECTROPUMP DATA
Description:
EVM PUMPS WITH ATEX 94/9/CE CONFORMITY
Model:
EVM
Year of manufacture:
SEE PLATE ON THE ELECTROPUMPE
2. INTRODUCTION
These safety instructions refer to the installation, ope-
ration and maintenance of EVM pumps (supplied
without motor) for use in areas with potentially ex-
plosive atmospheres.
Combined unit (motor+plus) is in accordance with
the ATEX Directive just when the pump and the re-
lative motor are approved ATEX.
Otherwise the unit can not be used in areas where
it is present the danger of explosions.
NOTE
These instructions must be followed, together with
the warnings given in the pump user manual.
Danger situations can arise if the pump is installed
incorrectly, therefore it can no longer be considered
as ideal for use in areas where the danger of explo-
sion exists.
Our EVM product should only be assembled by qua-
Legal office
Via Campo Sportivo, 30
Telephone: 0463/660411
Telefax:
0463/422782
lified and authorised personnel. The personnel in
charge of assembly and maintenance must be in-
structed and have suitable training regarding poten-
tially explosive areas.
Pump use and maintenance operations must respect
the connection indications, norms and regulations
that follow.
These regulations must be made known and availa-
ble to those who use the EVM product.
3. INDEX
2. INTRODUCTION
3. INDEX
4. PUMP INSTALLATION
5. PLATE DATA REGARDING
SAFETY
6. EARTH CONNECTIONS
7. INSTALLATION
8. MAINTENANCE AND REPAIRS
9. DECLARATION OF CONFORMITY
4. PUMP INSTALLATION
4.1. SUITABILITY OF THE PUMP IN THE INSTAL-
LATION AREA
If the pump is used in areas where the danger of ex-
plosion exists, make sure it is suitable for area clas-
sification and the characteristics of the flammable
substances present in the plant.
The essential safety requisites against the risk of ex-
plosion in classified areas are dictated by the 94/9/CE
European directive dated 23 March 1994 (regarding
apparatus) and the 1999/92/CE directive dated 16
December 1999 (regarding plants). The classification
criteria of areas where the risk of explosion exists are
dictated by the EN 60079-10 and EN 1127-1 norms.
4.2. AREAS WHERE GAS, VAPOUR OR FLAMMA-
BLE CLOUDS ARE PRESENT
According to technical and legal dispositions, the fol-
lowing factors must be taken into consideration
when selecting the type of pump to be used:
- Group classification: mines (group I), surface sy-
stems (group II);
- Area classification: 0, 1, 2 (for which apparatuses
of categories 1, 2, 3 respectively are suitable);
- Characteristic of the flammable substances present
GB
page
7
page
7
page
7
page
8
page
9
page
9
page 10
page 28
EVM – 7