Leds And Interfaces; Table 2-2: Installation Tools - Baicells Nova846 Installation Manual

Outdoor 8x5w two-carrier tdd enodeb
Hide thumbs Also See for Nova846:
Table of Contents

Advertisement

Nova846 Outdoor 8x5W Two-Carrier TDD eNodeB Installation Guide
Power plug
Ethernet cable
Ground cable
RF antenna cable
RF antenna
Optical fiber

Table 2-2: Installation Tools

Level bar
Wrench
Cable vice (crimper)

2.2 LEDs and Interfaces

Figure 2-2, Table 2-3, and Table 2-4 explain the eNB's LED status indicators and interfaces.
The plug that connects the power cable to the electricity supply
Outdoor CAT6, shorter than 328 feet (100 meters)
It is suggested that the diameter of the cable is .3 inches ± .04 inches
(7 mm ± 1 mm).
• If the length of lead is more than 33 feet (10 meters), 6 AWG (10 mm²)
grounding cable should be used.
• If the length of the lead is less than 33 feet (10 meters), 10 AWG
(10 mm²) grounding cable should be used.
50 ohm feeder, ½ jumper
Omni or directional dual polarized antenna
Optical fiber (armor). It is suggested that the diameter of the cable is
.3 inches ± .04 inches (7 mm ± 1 mm).
Marker pen
Percussion drill and
drill heads
Tape measure
11
Knife
Hammer
0.05 cm (5 mm) L-
shape Allen wrench
Pliers
Phillips-head
screwdriver
T7 screwdriver head

Advertisement

Table of Contents
loading

Table of Contents