Download Print this page

Regency Fireplace Products Onyx EX110 Instructions For Use & Installation page 26

Led electric fire range with thermostatic remote control

Advertisement

NOTE: Framing may be constructed of combustible material (I.e. 2 x 4/2 x 6) and does not require steel studs.
NOTE: The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete).which must be the full width and depth
of appliance.
This may be the floor, or raised up on a platform to enhance its visual impact.
Note: Measurement (B) does not include height of platform base if raised off the ground.
Example 1/2"(13 mm) thick platform base = 25-3/4" (654 mm) framing height.
26
FRAMING INSTALLATION (SINGLE SIDED)
B
A
ONYX
A
EX110
44-13/16"
(1138 mm)
(641 mm)
EX150
60-9/16"
(1538 mm)
(641 mm)
EX190
78-1/4"
(1988 mm)
(641 mm)
C
B
C
25-1/4"
12-7/16"
(316 mm)
25-1/4"
12-7/16"
(316 mm)
25-1/4"
12-7/16"
(316 mm)

Advertisement

loading

This manual is also suitable for:

Onyx ex150Onyx ex190228-062228-074228-080