Regency Fireplace Products P36D-NG1 Owners & Installation Manual

Zero clearance direct vent gas fireplace
Hide thumbs Also See for P36D-NG1:
Table of Contents

Advertisement

Quick Links

WARNING:
If the information in these instructions are not followed exactly, a fi re or
explosion may result causing property damage, personal injury or loss
of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and liquids in the
vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed installer, service
agency or the gas supplier.
Tested by:
918-522b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
P36D-1 Zero Clearance
Direct Vent Gas Fireplace
MODELS:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
P36D-NG1 Natural Gas
Owners & Installation Manual
FOR YOUR SAFETY
What to do if you smell gas:
 Do not try to light any appliance
 Do not touch any electrical switch: do not
use any phone in your building.
 Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
 If you cannot reach your gas supplier, call
the fi re department.
P36D-LP1 Propane
01/14/10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P36D-NG1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Regency Fireplace Products P36D-NG1

  • Page 1 P36D-1 Zero Clearance Direct Vent Gas Fireplace MODELS: P36D-NG1 Natural Gas P36D-LP1 Propane Owners & Installation Manual WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, a fi re or What to do if you smell gas: explosion may result causing property damage, personal injury or loss ...
  • Page 2 WARNING HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
  • Page 3: To The New Owner

    To the New Owner: Congratulations! ® You are the owner of a state-of-the-art Gas Fireplace by REGENCY FIREPLACE PROD- UCTS The P36D-1 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model P36D-1 has been approved by Warnock Hersey for both safety and effi...
  • Page 4: Table Of Contents

    Unit installation with Vertical Termination ....33 General Safety Information..........8 Direct Vent System (Flex) Installation Procedures ..34 Installation Checklist .............8 P36D-NG1 System Data ..........35 P36D-LP1 System Data ..........35 Locating Your Gas Fireplace .........9 High Elevation .............35 Manufactured Mobile Home Additional Requirements ..9 Gas Line Installation ............35...
  • Page 5 TABLE OF CONTENTS OPERATING INSTRUCTIONS REGENCY™ SERIES OPTIONS Operating Instructions ..........49 The Kensington ® Front Installation ......60 Shutdown Procedure ...........49 The Balmoral ® Front Installation ........61 2-panel Door Installation..........62 First Fire ..............49 3-panel Door Installation..........62 Lighting Procedure ............49 Optional Fan Installation ..........63 Aeration Adjustment ............49 ®...
  • Page 6: Safety Label

    SAFETY LABEL This is a copy of the label that accompanies each P36D-1 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open.
  • Page 7: Requirements

    REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 8: Installation

    INSTALLATION UNIT DIMENSIONS 33"(838mm) 36" (914mm) 36"(914mm) 17-1/8"(435mm) HAMPTON FACEPLATE DIMENSIONS 43-1/4” (1099mm) 1-1/4” (32mm) 32-1/4” (819mm) ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 9: Important Message

    fl ammable vapours and liquids). codes, with the current Canadian or National The P36D-NG1 or P36D-LP1 Direct Vent Gas Codes, CAN1-B149 or ANSI Z223.1 Fireplace must be installed in accordance Installation Codes.
  • Page 10: Locating Your Gas Fireplace

    INSTALLATION This includes: MANUFACTURED MOBILE HOME 1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label 30,000 Btu/h) ADDITIONAL after burning appliance for 15 minutes. REQUIREMENTS 2) If required, adjusting the primary air to ensure that the fl...
  • Page 11: Clearances

    INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fi replace and vent system be installed only in accordance with these instructions. IMPORTANT: See Barcelona Series Framing Note for framing notes on Barcelona Series Fronts.
  • Page 12: Regency ® Clearances

    INSTALLATION ® REGENCY CLEARANCES Clearances for Bay Front, Flush Front Clearances for Barcelona Front & Full Screen Doors Clearances for The Balmoral Front Clearances for The Kensington ® Front ® HAMPTON CLEARANCES TRIPOLI ARCH DOOR CLEARANCES ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 13 INSTALLATION Durok, Wonderboard or other 6" Standoff non-combustiblematerial (cement board 6" Standoff 6" Standoff ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 14: Regency ® Combustible Mantel Clearances

    INSTALLATION ® REGENCY SERIES COMBUSTIBLE MANTEL CLEARANCES Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
  • Page 15: Regency Combustible Mantel Clearances

    INSTALLATION REGENCY ™ COMBUSTIBLE MANTEL CLEARANCES Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
  • Page 16: Hampton ® Combustible Mantel Clearances

    INSTALLATION ® HAMPTON COMBUSTIBLE MANTEL CLEARANCES Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
  • Page 17: Regency ® Mantel Leg Clearances

    INSTALLATION ® REGENCY MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: Maximum 1-1/2" projection at 2" minimum clearance. P36D Kensington Front Width: 42-5/8" Fireplace Balmoral Front Width: 40-5/8" Regency Series Front 2" Measure from 5" edge of Front. Allowable mantel leg projection.
  • Page 18: Framing And Finishing

    INSTALLATION FRAMING AND FINISHING NOTE: See next page for important Note: 40-1/2" (1029mm) is the minimum 1) Determine the total thickness of facing height for both fl ex termination or material (e.g. drywall plus ceramic tiles) to Barcelona™ Series framing note. Simpson Dura-Vent venting.
  • Page 19: Barcelona ™ Series Framing Note

    INSTALLATION ™ BARCELONA SERIES FRAMING NOTE ™ When installing the optional Barcelona Front Series, a non-combustible material 12" (305mm) above the unit and 6" (153mm) on each side must be used. See diagram 1. The Barcelona Front ™ Series also requires steel stud framing above and on each side of the unit. See diagram 1. Front Framing Dimensions using the Barcelona Series Option Non-combustible...
  • Page 20: Unit Assembly Prior To Installation

    INSTALLATION UNIT ASSEMBLY Side Nailing Strips "C" Screw Position: For a facing material depth of 1-1/4" (32mm), PRIOR TO Determine the total thickness of facing material the top facing support must be reversed. (e.g. drywall plus ceramic tiles) to allow the INSTALLATION fi...
  • Page 21: Exterior Vent Termination Locations

    INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS Canada Minimum Clearance Requirements Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window Vertical clearance to ventilated soffi t located above the terminal within a horizontal distance of 2 feet (61cm) 18"(46cm) 18"(46cm) from the center line of the terminal (check with the local code)
  • Page 22: Venting

    INSTALLATION VENTING DIRECT VENT SYSTEM (FLEX) HORIZONTAL TERMINATIONS ONLY These venting systems, in combination with the P36D-1 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent Termination Locations"...
  • Page 23: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    INSTALLATION 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Description Selkirk American Metal Security ICC Excel Simpson Metal-Fab™ ® Direct Temp™ Secure- Vent® Direct Direct Vent Pro Products®...
  • Page 24 INSTALLATION Description Selkirk American Metal Security ICC Excel Simpson Metal-Fab™ ® Direct Temp™ Secure- Vent® Direct Direct Vent Pro Products® Sure Seal Amerivent Direct Attic Insulation Shield 12” 46DVA-IS 4DAIS12 SV4RSA N/A@ FPI Attic Insulation Shield - 36” 4DAIS12 TM-4AS Cold Climates Basic Horizontal Termination Kit (A) Disc.
  • Page 25: Rigid Pipe Venting Systems

    INSTALLATION RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations The minimum components required for a basic Flat Wall Installation horizontal termination are: Wall Thickness (inches) Vent Length Required (inches) Horizontal Termination Cap 4" - 5-1/2" 6" Elbow 7" - 8-1/2" 9"...
  • Page 26: Venting Arrangements Horizontal Termination

    INSTALLATION VENTING ARRANGEMENTS HORIZONTAL TERMINATION RIGID PIPE AND FPI DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 elbow (two 45 elbows equal one 90 elbow). Note: Must use optional rigid pipe adaptor (Part # 510-994) when using Rigid Pipe venting systems.
  • Page 27: Venting Arrangements Vertical Termination

    INSTALLATION VENTING ARRANGEMENTS VERTICAL TERMINATION RIGID PIPE SYSTEM (Propane & Natural Gas) The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90 elbow, with rigid pipe vent systems for Propane and Natural Gas. •...
  • Page 28 INSTALLATION The P36D-1 is approved for a 40 ft. straight vertical, with rigid pipe vent systems for Propane and Natural Gas, as per the diagram 1. The shaded area in the diagram 1 shows all allowable combinations of straight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas.
  • Page 29: Horizontal Venting With Two (2) 90 Elbows

    INSTALLATION HORIZONTAL VENTING WITH TWO (2) 90 ELBOWS One 90 elbow = Two 45 elbows. Option H + H1 W i t h t h e s e o p t i o n s , 0' Min. 2' Max. maximum total pipe length 1' Min.
  • Page 30: Vertical Venting With Two (2) 90 Elbows

    INSTALLATION VERTICAL VENTING WITH TWO (2) 90 ELBOWS One 90 elbow = Two 45 elbows. Option V + V1 With these options, max. total pipe length is 30 feet with min. 0' Min. 2' Max. 1' Min. of 7 feet total vertical and max. 1' Min.
  • Page 31: Vertical Termination With Co-Linear Flex System

    INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM Masonry chimneys may take various contours which the fl exible liner will accommodate. However, THE APPLIANCE MUST NOT BE keep the fl exible liner as straight as possible, avoid unnecessary bending. CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL The Air Intake pipe must be attached to the inlet air collar of the termination cap.
  • Page 32: Venting Arrangement - Vertical Terminations

    INSTALLATION VENTING ARRANGEMENT - VERTICAL TERMINATIONS CO-LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES FOR BOTH RESIDENTIAL & MANUFACTURED HOMES Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 33: Unit Installation With Horizontal Termination

    INSTALLATION UNIT INSTALLATION WITH b) Horizontal runs of vent must be supported every three feet. Wall straps HORIZONTAL TERMINATION are available for this purpose. Install the vent system according to the 5) Mark the wall for a 10" x 10" square hole. The center of the square hole should line up with manufacturer's instructions included with the centerline of the horizontal pipe.
  • Page 34: Unit Installation With Vertical Termination

    INSTALLATION 4) Assemble the desired lengths of pipe and UNIT INSTALLATION WITH elbows. Ensure that all pipes and elbow VERTICAL TERMINATION connections are in the fully twist-locked position and sealed. 1) Maintain the 1-1/4" clearances 5) Cut a hole in the roof centered on the small (air spaces) to combustibles drilled hole placed in the roof in Step 2.
  • Page 35: Direct Vent System (Flex) Installation Procedures

    INSTALLATION 4) Separate the 2 halves of the wall thimble and the vertical height must be increased. A poor securely fasten the one with the tabs to the draft, or down drafting can result from high outside wall making sure that the tabs are wind conditions near big trees or adjoining N o t e : m a k e...
  • Page 36: P36D-Ng1 System Data

    INSTALLATION The manifold pressure is controlled by a regulator always best to consult with your local authorities P36D-NG1 SYSTEM DATA built into the gas control, and should be checked and the CAN/CGA B149 installation code. at the pressure test point.
  • Page 37: Conversion From Ng To Lp

    INSTALLATION CONVERSION KIT# 514-969 FROM NG TO LP for P36D-1 / P36-4 / U32-4 / U37-1 using SIT 820 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Pull off the pilot cap to expose the pilot For P36D-1 / P36-4 Only: Each Kit contains one LPG...
  • Page 38: Installation Of The Dc Sparker

    INSTALLATION Reinstall new burner orifi ce LPG 16) Verify that if the conversion is from Installation of the DC Sparker: stamped #52 and tighten. NG to LPG, the screw must be re- assembled with the red o-ring visible 21) Locate the Piezo Ignitor situated at the 10) Turn control knob to the “OFF”...
  • Page 39 INSTALLATION 25) Locate the ground lug. 28) Install the 1/2" bushing to the heat 32) Mount the heat shield to the DC Sparker. shield. Secure into place with the velcro, which is For P36D-1 / P36-4 Only: provided in the kit. 25a) By the receptical box, left of the unit.
  • Page 40: Optional Brick Panels

    INSTALLATION OPTIONAL BRICK PANELS 4) Install the 2 brick retaining clips, one on each side. 1) Undo the bottom 2 door latches and open and remove glass door. Remove logs. Note: The logs must not be in the unit. 2) Insert the back brick panel fi rst by carefully slipping it between the back wall of the fi...
  • Page 41: Log Set Installation

    INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the Place the Log 02-75 on the rear log support pins with the diagrams. If logs are broken do not use the unit until fl at side to the back. they are replaced.
  • Page 42 INSTALLATION Position Log 02-53 across the cutouts in Logs 02-75 and 02-51 with the notch on the left side of the log fi tting into the 2nd grate tab. 02-53 02-75 5th Grate Tab 02-51 Place the bottom left front edge of Log 02-55 against the rear bracket on the burner tray and rest the log on the cutout on Log 02-53.
  • Page 43 INSTALLATION Place Log 02-52 between Logs 02-51 and 02-75 and on Sit Log 02-50 on the front left side of the burner. Push the indentation on Log 02-54. The bottom right end sits the back of the log against the 2 front brackets with the behind the rear grate tab.
  • Page 44 INSTALLATION 10) Place the embers on the front of the burner tray in the 02-51 places shown on the photos below. 02-54 Separate platinum embers and place on the front burner on and around the embers. Avoid stacking platinum embers. Platinum embers may be placed over burner ports.
  • Page 45: Standard Flush Door

    INSTALLATION STANDARD FLUSH DOOR The standard fl ush door comes with a black frame. To install the frame, Be careful that the glass gasket does not roll up; there must be a gap simply hook the top door fl ange onto the top of the unit and swing the between the gasket and the door lip to ensure that the door sits securely door towards the unit, see diagram 1.
  • Page 46: Remote Control (Optional)

    REMOTE CONTROL WALL THERMOSTAT WALL SWITCH (OPTIONAL) (OPTIONAL) (OPTIONAL) Use the FPI Remote Control Kit approved for 1) Run the wire through the right or left side A wall thermostat may be installed if desired, this unit. Use of other systems may void your inlet opening.
  • Page 47: Wiring Diagrams

    INSTALLATION WIRING DIAGRAMS NOTE: Even if the fan is not purchased This heater does not require a 120V A.C. sup- (Do not cut the ground terminal off under any circumstances.) with the unit, it is still a good idea ply for operation. In case of a power failure, the burner switch and the optional remote control/ to bring power to the receptacle box thermostat will continue to operate.
  • Page 48 INSTALLATION PROPANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 49: Optional Fan Installation

    INSTALLATION OPTIONAL FAN 6) Slide the thermodisc/cover assembly into 11) Attach the two control boxes to the bottom the bracket clip on the underside of the louver and tighten the 2 screws on the left INSTALLATION fi rebox. Check that no wire will touch the side and 1 screw on the right side.
  • Page 50: Operating Instructions

    OPERATING INSTRUCTIONS OPERATING 3) Turn gas control knob counterclockwise During the fi rst few fi res, a white fi lm so indicator points to the "PILOT" position. may develop on the glass front as part INSTRUCTIONS Depress the gas control knob fully. Depress of the curing process.
  • Page 51: Maintenance

    MAINTENANCE COPY OF THE LIGHTING PLATE INSTRUCTIONS Blower: FPI gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON. This sound will increase or decrease in volume depending on the speed setting of your fan speed control.
  • Page 52: General Vent Maintenance

    MAINTENANCE 5) The appliance and venting system must be DOOR GLASS LOG REPLACEMENT inspected before use, and at least annually, by a qualifi ed fi eld service person, to ensure Your FPI fireplace is supplied with high The unit should never be used with broken logs. that the fl...
  • Page 53: Removing Valve

    MAINTENANCE 7) Lift out the bottom brick panel. 16) Remove the 4 Phillips head screws from 5) Replace door on the stove the sides of the valve bracket and remove and check the seal. valve. Hint: If you are using black pipe, ensure that there is a union by the valve, otherwise removal will be almost impossible.
  • Page 54: Regency Options

    ® REGENCY OPTIONS FLUSH TRIM FLUSH LOUVERS DOUBLE SCREEN DOOR 1) Install the top louver by sliding the two Attach the round magnets to the back of the bracket clips into the brackets located top trim piece and to the bottom trim piece, 1) Pull out the top louver.
  • Page 55: Bay Door

    ® REGENCY OPTIONS 2) Install bottom louver by sliding the two BAY DOOR BAY TRIM bracket clips into the brackets located underneath the bay door. Secure with 1 The Bay louvers MUST be used Attach supplied magnets each to the back of screw into each Bottom Louver Mounting the top and bottom trim pieces, and attach trim with the Bay glass option.
  • Page 56: Full Screen Door Installation

    ® REGENCY OPTIONS FULL SCREEN DOOR INSTALLATION 1) Before beginning the installation, remove the Screen Doors from the Full Screen Door Frame by fully opening the doors and lifting up off of the hinges. See important note in step 7. 2) Full Screen Door Frame Installation Cut-Out a) Before attaching the Full Screen Door Frame to the unit, loosen the...
  • Page 57 ® REGENCY OPTIONS 3) Install the hinges to the hinge brackets on the left and right side of the bottom of the outer frame, secure using 2 x #8 Philips Head Screws Restrain per hinge. Bracket Hinge Bracket Right Side of Bottom Grill 6) Slide the Top Grill into the louver brackets located on the inside top...
  • Page 58: Tripoli Screen Door

    ® REGENCY OPTIONS TRIPOLI SCREEN DOOR When installing the optional Tripoli Screen Door Series, a non-combustible material 12" (305mm) above the unit and 6" (153mm) on each side must be used (see Diagram 1). The Tripoli Screen Door Series also requires steel stud framing above and on each side of the unit (refer to Diagram 1). Diagram 1 Option #1: Option #2:...
  • Page 59 ® REGENCY OPTIONS Note: The facing material has to go on after the unit is set. 4) Place bracket under the Flange. Secure with 2 screws as indicated in Diagram 4. 1) Remove Glass Door. Refer to P36 Manual. 2) Remove 2 screws and bracket as indicated (refer to Diagram 2). Remove bracket Diagram 4 Remove both screws...
  • Page 60 ® REGENCY OPTIONS 6) Install Top Support Frame 8) Attach Top and Side Support Frame a) Ensure the Side Supports are aligned with the correspond Slide in the Top Support Frame using the slots as a guide. Secure hole on the Top Support Frame, then secure with 1 screw. and re-tighten the screws to the unit.
  • Page 61: Regency™ Series Options

    REGENCY™ SERIES OPTIONS ® THE KENSINGTON FRONT INSTALLATION ® 1) Bend tabs downwards located at the back of The Kensington 4) Remove existing control switch box from under fi rebox by disconnect- Front. ing wires connected to the valve at TH-TH/TP terminals and discard. Bend tabs downwards.
  • Page 62: The Balmoral ® Front Installation

    REGENCY™ SERIES OPTIONS ® THE BALMORAL FRONT INSTALLATION 4) Remove existing control switch box from under fi rebox by disconnecting 1) Bend tabs located at the back of the Balmoral Front upwards 90 wires connected to the valve at TH-TH/TP terminals and discard. degrees.
  • Page 63: 2-Panel Door Installation

    REGENCY™ SERIES OPTIONS THE KENSINGTON ® & BALMORAL FRONT 2-PANEL DOOR INSTALLATION 3-PANEL DOOR INSTALLATION 1) Install sub-frame by hooking top over glass door, push in bottom of 1) Install sub-frame by hooking top over glass door, push in bottom of frame and secure with 2 screws.
  • Page 64: Optional Fan Installation

    REGENCY™ SERIES OPTIONS THE KENSINGTON, BALMORAL FRONT OPTIONAL FAN INSTALLATION 4) Tuck wires in new fan control box and secure with screw. 1) Remove fan cover by undoing screw. Fan Control Box Fan Cover 2) Disconnect fan switch wires and discard fan cover with wires. Secure with screw.
  • Page 65: Hampton Options

    ® HAMPTON OPTIONS HAMPTON ® CAST FACEPLATE 1) Remove top louver and grill. 5) Slide top piece of faceplate into side faceplates by fi tting mounting plates into brackets. 2) Open bottom louver and grill. 3) Install the left side faceplate by pushing in at the side of the fi rebox and line up with top and bottom holes on side.
  • Page 66: Hampton ® Cast Grills

    ® HAMPTON OPTIONS ® HAMPTON CAST GRILLS 1) Remove the 3 faceplate mounting phillips head screws from the 5) Install hinge to bracket then secure with screw. inside top of fi rebox, and discard if necessary. Hinge Bracket 2) Place top grill in brackets located inside top of fi rebox as shown. 6) Place something underneath bottom grill to prevent scratching.
  • Page 67: Parts List

    PARTS LIST MAIN ASSEMBLY Part # Description Part # Description Part # Description 948-253 Door Handle 780-901 Brick Panel Set - Standard Brown 43) 910-813 Power Cord (120 Volts) 510-026 Hinge Bracket - Left/Right 780-902 Brick Panel Set - Standard Red 46) 910-330 Fan Speed Control Switch 948-045...
  • Page 68: Burner Assembly & Log Set

    PARTS LIST BURNER ASSEMBLY & LOG SET Part # Description 52) 910-190 Piezo Ignitor & Nut 53) 780-021 Gasket - Valve Access Plate NG/LP 54) 910-421 Pilot ON/OFF 3" Extension Knob 55) 910-422 Flame HI/LOW 3" Extension Knob 780-574/P Valve Assy - Natural Gas 780-576/P Valve Assy - Propane 56) *...
  • Page 69: Regency ® Bay Front Assembly

    PARTS LIST REGENCY ® BAY FRONT ASSEMBLY Part # Description Part # Description 780-931 Bay Front Complete 510-988 Bay Louvers - Black 103) 940-092/P Side Glass 510-993 Bay Louvers - Steel/Black 107) 936-243 Glass Gasket 510-990 Bay Louvers - Gold/Black 108) 940-094/P Center Glass 510-992...
  • Page 70: Regency ® Flush Front Assembly

    PARTS LIST ® REGENCY FLUSH FRONT ASSEMBLY Part # Description Part # Description 152) * Flush Glass Trim 132) 512-518 Flush Door Assembly 904-196 Magnet 135) 940-090/P Glass (Flush) 136) 936-155 Glass Gasket (Tadpole) 510-932 Flush Glass Trim (Set) - Gold 904-691 U-Clip 150) *...
  • Page 71: Hampton Cast Faceplate & Grill Assembly

    PARTS LIST ® HAMPTON CAST FACEPLATE & GRILL ASSEMBLY Part # Description 513-971** Cast Faceplate (Set) 201) * Cast Faceplate - Right 202) * Cast Faceplate - Top 203) * Cast Faceplate - Left 513-981** Cast Grills (Set) 204) * Top Grill 205) * Bottom Grill...
  • Page 72: Warranty

    WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Excalibur Product.
  • Page 73 In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency Fireplace Products is pleased to extend this Limited ® Lifetime Warranty to the original purchaser of a Regency Product.

This manual is also suitable for:

P36d-lp1

Table of Contents