Zero clearance direct vent gas fireplace (52 pages)
Summary of Contents for Regency Fireplace Products Bellavista B41XTCE-NG10
Page 1
Owners & ™ Regency Bellavista B41XTCE Installation Manual Gas Fireplace MODELS: B41XTCE-NG10 B41XTCE-LP10 www.regency-fire.com Bellavista B41XTCE Video WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Page 2
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The Bellavista™ ® B41XTCE has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The Bellavista™ B41XTCE has been approved by Warnock Hersey/Intertek for both safety and efficiency.
MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: ® VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2014 • CSA 2.33-2014 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN / CGA 2.17-M91.
table of contents Massachusetts only Code - CO Detector ......6 Unit installation with Vertical Termination ....34 Unit Dimensions ............7 Gas Line Installation ............34 Important Message ............8 Pilot Adjustment ............35 Before You Start ............8 High Elevation .............35 General Safety Information..........8 885 S.I.T. Valve Description .........35 Installation Checklist .............9 Gas Pipe Pressure Testing ..........35 Locating Your Gas Fireplace .........9...
Page 5
safety decal This is a copy of the label that accompanies each Bellavista™ B41XTCE Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. ®...
requirements MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
installation IMPORTANT MESSAGE 3) See general construction and assembly YOUNG CHILDREN SHOULD BE CARE- instructions. The appliance and vent should SAVE THESE FULLY SUPERVISED WHEN THEY ARE be enclosed. IN THE SAME AREA AS THE APPLI- INSTRUCTIONS ANCE. TODDLERS, YOUNG CHILDREN 4) This appliance must be connected to the AND OTHERS MAY BE SUSCEPTIBLE specified vent and termination cap to the...
installation INSTALLATION This includes: 4) This appliance is Listed for bedroom CHECKLIST 1) Clocking the appliance to ensure the correct installations using the standard Remote firing rate (rate noted on label), after burning (millivolt thermostat system). Some areas appliance for 15 minutes. may have further requirements, check local 1) Locate appliance codes before installation.
installation CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. WARNING Caution Requirements Fire hazard is an extreme risk...
installation MANTEL CLEARANCES Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
installation MANTEL LEG CLEARANCES 9” Side Wall (Measured from side of Fireplace Opening) 4” 7” Allowable mantel leg projection. NON-COMBUSTIBLE REQUIREMENTS 46-11/16" [1186mm] 6" [152mm] NON-COMBUSTIBLE BOARD SUPPLIED W/UNIT No Combustible 11-5/8" [295mm] Materials in this Area NO FACING OR FINISHING MATERIAL IN THIS AREA 3-9/16"...
installation FRAMING & FINISHING 1. Frame in the enclosure for the unit with framing material. Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed. 2. For exterior walls, insulate the enclosure to the same degree as the rest of the house; apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.) WARNING: Failure to insulate and add vapor barriers to the inside of the exterior wall will result in operational and performance problems including, but not limited to: excessive condensation on glass doors, poor flame package, carbon, blue flames etc.
installation 7. Non-combustible material (ie. tile, slate, etc) may be brought up to the edge of the glass door of the unit. Minimum clearances must be adhered to, this will assure ease of glass door removal and access to the lower panel. NOTE: Non-combustible finishing materials may be of any thickness desired.
installation UNIT ASSEMBLY PRIOR TO INSTALLATION BEFORE YOU START The Top Nailing Support, the Side Nailing Strips, the 2 Top Standoffs and the Flue Collar must be correctly positioned and attached before the fireplace is moved into position. TOP STANDOFF ASSEMBLY The top standoffs are shipped in a flat position and must be folded into shape and attached.
installation CONVERSION TO TOP VENT Note: This conversion must be done prior to the unit being placed in position. The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented. 4) From the outside rear of the firebox, remove the intake collar assembly.
Page 18
installation 8) From the outside top of the firebox - completely remove the insulation 11) From the outside top of the firebox, install the intake collar assembly. under the cover plate as shown and discard. Secure with 4 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over tighten.
installation VENTING INTRODUCTION The B41XTCE uses the "balanced flue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
installation EXTERIOR VENT TERMINATION REQUIREMENTS Minimum Clearance Requirements Canada Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) 24"(60cm) 24"(60cm) from the center line of the terminal (check with the local code)
installation 5" X 8" RIGID PIPE CROSS REFERENCE CHART ONLY 5” X 8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI. Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Description Selkirk ICC Excel...
Page 22
installation Description Selkirk ICC Excel Simpson Metal-Fab™ Direct Temp™ Direct Direct Vent Pro ® Sure Seal Attic Insulation Shield 12” 58DVA-IS N/A from FPI Basic Horizontal Termination Kit (A) 5DT-HKA Horizontal Termination Kit (B) 58DVA-KHA 5DT-HKB Vertical Termination Kit 58DVA-VHA 5DT-VKC High Wind Vertical Cap 58DVA-VCH...
installation VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS FLEX VENT OR RIGID PIPE 5" X 8" The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system. A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. For horizontal terminations the Regency Direct Vent Flex System may be used for installations upto a maximum continuous vent length of 10ft (3.0m).
installation HORIZONTAL TERMINATIONS FLEX VENT 5" X 8" These venting systems, in combination with the B41XTCE Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations"...
Page 25
installation HORIZONTAL TERMINATIONS RIGID PIPE 5" X 8" Horizontal Termination Top Vent - No Vertical Rise • When venting with a 90° elbow directly off the unit Flex vent or approved Rigid Vent System • Max. 3 ft. horizontal run Rear Vent w/ Horizontal Termination •...
Page 26
installation HORIZONTAL TERMINATIONS ASTROCAP XL & RIGID REAR VENT KIT FOR CORNER INSTALLATIONS RIGID PIPE 5" X 8" Designed for a minimum vent configuration when using a rear vent Placement of the Unit into the Corner application with a horizontal termination in a corner installation. Back Top Corner of Unit to Wall 3"...
installation RIGID PIPE VENTING SYSTEMS BASIC HORIZONTAL & VERTICAL TERMINATIONS Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal Vertical and vertical installations. Many items are offered Termination in decorative black, as well as galvanized finish. The minimum components required for a basic Storm Collar Horizontal Termination are:...
installation VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 (two 45 elbows equal one 90 elbow). • Maintain clearances to combustibles as listed in "Clearances" section • Horizontal vent must be supported every 3 feet. •...
installation HORIZONTAL TERMINATIONS TWO (2) 90 ELBOWS (RIGID PIPE 5" X 8") One 90 elbow = Two 45 elbows. Option H + H1 With these options, maximum total pipe 0' Min. 2' Max. length is 30 feet with 1' Min. 3' Max. minimum of 6 feet total vertical and maximum 8 2' Min.
installation VENTING ARRANGEMENTS FOR VERTICAL TERMINATIONS The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90 elbows, with Rigid Pipe Venting Systems for Propane and Natural Gas. Two 45 elbows equal to one 90 elbow.
installation VERTICAL TERMINATIONS THREE (3) 90 ELBOWS (RIGID PIPE 5" X 8") One 90 elbow = Two 45 elbows. Option V + V1 H + H1 W i t h t h e s e o p t i o n s , maximum total pipe length 0' Min.
Page 32
installation UNIT INSTALLATION 5) Assemble the desired combination of pipe 7) Ensure that the pipe clearances to and elbows to the appliance adaptor and combustible materials are maintained WITH HORIZONTAL twist-lock for a solid connection. (Diagram 5). Install the termination cap. TERMINATION Note: For best results and optimum Note: If installing termination on a vinyl...
Page 33
installation UNIT INSTALLATION NOTE: Horizontal sections must be sup- ASTROCAP XL ported at intervals not exceeding 3 WITH HORIZONTAL feet (0.9 meter). (Flame picture and DIMENSIONS (946-623/P) performance will be affected by sags TERMINATION in the liner). 5" X 8" VENTING 4) Separate the 2 halves of the wall thimble and (Flex Vent Systems) securely fasten the one with the tabs to the...
installation UNIT INSTALLATION 4) Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow con- WITH VERTICAL nections are in the fully twist-locked position and sealed. TERMINATION 5" X 8" VENTING (Rigid Vent Systems) Diagram 4 MUST USE RIGID PIPE Roof Pitch Minimum Vent Height ADAPTOR #770-994...
installation PILOT ADJUSTMENT GAS PIPE B41XTCE -NG10 System Data PRESSURE TESTING Periodically check the pilot flames. Correct For 0 to 4500 feet altitude flame pattern has two strong blue flames: Burner Inlet Orifice Sizes: The appliance must be isolated from the gas 1 flowing around the flame sensor and 1 supply piping system by closing its individual flowing across the burner (it does not have...
B41XT installation BRICK PANEL INSTALLATION BRICK PANEL INSTALLATION Must install one of the following: Brick Panels, Stainless Steel or Black Enamel Panels. Dangerous operating conditions may occur if the panels are not installed or if installed with broken panels. Handle with care. DO NOT FORCE INTO POSITION. 1) Unwrap the Brick Panels from the protective wrapping.
B41XT installation OPTIONAL BLACK ENAMEL OPTIONAL BLACK ENAMEL PANEL INSTALLATION PANEL INSTALLATION Black Enamel Panels • Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. •...
Page 38
B41XT installation 4) Remove 1 screw (see inset A), position right side panel in fi rebox - 7) Carefully position and fi t the top bracket in place by ensuring the position panel clip in place and secure with 1 screw (see inset B). tabs of the bracket fi...
B41XT installation LOG SET INSTALLATION LOG SET INSTALLATION Installation of Brick or Black Enamel Panels must be completed before installing the log set. Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replac ed. Broken logs can interfere with pilot operation.
Page 40
B41XT installation 5) Place Log I on the left side of the burner, directly in front of Log A. 8) Slide the left side of Log G back until it touches the tab on the burner Position Log I so it fi ts into the pin on the burner as shown below. shown below.
Page 41
B41XT installation 11) Position Log E on top of Log G - fi t Log E into the pin on Log G as shown below. Diagram 13 14) Position Log C on top of Log H. Log C fi ts into the pin in Log H. as shown below.
Page 42
B41XT installation 16) Place the lava rocks on the burner in front of the logs as shown below. 17) Separate platinum embers and place on the front burner on and Be careful not to overlap the lava rock and ensure the burner ports around the lava rocks.
Page 43
installation AC POWER ADAPTOR INSTALLATION (FOR SUREFIRE SYSTEMS) An AC power adaptor is supplied with this appliance and may be installed as a constant power source for the SureFire system. NOTE: AC power adaptor is not required when using GTMF Remote with fan control module and must be disconnected. IMPORTANT: Recommend removing the 4-AA batteries in the SureFire receiver.
installation WIRING DIAGRAM This heater does not require a 120V A.C. supply for operation but it is highly recommended to install the supplied AC adaptor to eliminate the need for batteries. In case of a power failure, the burner switch and the optional remote control will continue to operate if batteries are installed in the receiver.. However, a 120V A.C.
B41XTE installation OPTIONAL FAN INSTALLATION OPTIONAL FAN INSTALLATION Important: 120 Volt AC power is needed for the fan switch and blower. 9) Slide the thermodisc/cover assembly onto the bracket clip on the The receptacle box will be installed on the left hand side of the unit left underside of the firebox.
installation WIRING DIAGRAM WITH OPTIONAL FAN SureFire™ Switch Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. 46 | Regency Bellavista™...
B41XT installation OPTIONAL ACCENT LIGHT INSTALLATION OPTIONAL ACCENT LIGHT INSTALLATION 8) Remove the 2 screws securing the base tray - lift base tray up and Accent Light Assembly Kit out. Diagram 4a and 4b. 910-814 Plug wiring + gasket 910-997 Halogen Bulb 940-363 Amber Glass...
Page 48
B41XT installation 12) Install each light assembly from the underside of the fl oor of the 14) Install two light diffusers on to the base tray. fi rebox. Secure with 2 screws as shown below. 15) Secure diffusers onto base tray from the backside of the tray with 2 screws.
Page 49
B41XT installation LINE VOLTAGE WIRING TO RECEPTACLE IN UNIT TO MAKE OUTLETS INDEPENDENT OF EACH OTHER AC Adaptor ELECTRICAL WORK MUST BE PERFORMED BY A QUALIFIED ELECTRICIAN Regency Bellavista™ B41XTCE-10 Gas Fireplace 08/12/14 918-864a...
installation FLUSH GLASS DOOR INSTALLATION The standard flush door comes with a black frame. To install the frame, Be careful that the glass gasket does not roll up; there must be a gap simply hook the top door flange onto the top of the unit and swing the between the gasket and the door lip to ensure that the door sits securely door towards the unit, see Diagram 1.
operating instructions OPERATING NORMAL OPERATING AERATION INSTRUCTIONS SOUNDS OF ADJUSTMENT GAS APPLIANCES 1) Read and understand these instructions before operating this appliance. The burner aeration is factory set but may need It is possible that you will hear some sounds from adjusting due to either the local gas supply or 2) Check to see that all wiring is correct and your gas appliance.
operating instructions LIGHTING PROCEDURE IMPORTANT: The remote control system supplied with this appliance has several options for starting/operating the appliance using the power button 3. After approximately 4 seconds the spark ignition system will spark for 60 and ON/OFF key on the hand held transmitter. seconds to light the main burner.
operating instructions COPY OF LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
maintenance MAINTENANCE DOOR GLASS by having excessive lateral runs, too many elbows, and exterior portions of the system INSTRUCTIONS being exposed to cold weather. Your Regency fireplace is supplied with high ® temperature 5mm-Ceramic glass. If your glass 4) Inspect joints, to verify that no pipe 1) Always turn off the gas valve before cleaning.
B41XT maintenance ACCENT LIGHT BULB REPLACEMENT BULB REPLACEMENT 1) Shut off electrical and gas supply. 8) Remove the 2 screws securing the base tray - lift base tray up and out. Diagram 4a and 4b. 2) Remove the glass door - see instructions in manual. 3) Remove the logs, lava rock and vermiculite if installed.
maintenance VALVE REPLACEMENT 8) Remove the 2 screws securing the burner INSTALLING VALVE tray - lift burner tray up and out. Diagram 4a and 4b. 1) Place new valve tray and gasket into position. 1) Shut off the gas and electrical supply. 2) Reinstall the 14 hold down screws.
parts list MAIN ASSEMBLY Part # Description Part # Description Firebox Assembly 506-086 Top Insulation Plate 506-517 Fan Assembly 506-074 Top Insulation 910-215/P Fan Motor (120 Volts) 506-513 Flue Collar Outer Assembly 556-095 Flue Collar Gasket 911-159 Power Cord 120V 506-000 Exhaust Gasket Mesh Guard...
warranty Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly ® before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.
Page 64
Register your Regency warranty online ® www.regency-fire.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and spe- cial offers on related products.
Need help?
Do you have a question about the Bellavista B41XTCE-NG10 and is the answer not in the manual?
Questions and answers