FITTING THE APPLIANCE
LOCATING THE ONYX
Your new Onyx may be installed virtually anywhere in your home.
However, when choosing a location ensure that the general
instructions are followed.
For best results, install out of direct sunlight.
The heater should ideally be fitted into/onto an internal flat
wall constructed from either wood studs and drywall,
block/brick. The fixings provided are for use on brick walls
ONLY. Please ensure that suitable fixings are used when
securing to any hollow or purpose built cavity.
NOTE: This appliance is not suitable for fitting to a Cavity
Wall, backing on to an outside wall, an open chimney or any
opening that may be subject to damp and draft, unless
adequate precautions are taken to avoid the appliance
coming into contact with moisture or excessive drafts. In
such installations, any existing chimney and/or purpose
provided air vents should be fully sealed.
For exterior/outside walls, insulate the enclosure to the same degree
as the rest of the house, apply vapor barrier and drywall, as per local
installation codes. Do not insulate the appliance itself.
Make sure there are no pipes or cables behind the area to be
drilled or cut.
Always ensure the appliance is adequately supported and sits on a
firm structure when mounting above floor level.
The appliance should ideally be located close to a suitable main
socket to enable connection. An extension could be run from an
existing socket outlet but this must be carried out by a suitably
qualified electrical engineer.
The electrical socket must be easily accessible to allow disconnection
when the appliance is fitted.
If the power cord is damaged, it must be repaired by the
manufacturer, its authorised service centre or professional person.
Ensure that curtains and furniture are not positioned close to the
chosen position, as this would create a potential fire hazard or block
the heater outlet ducts.
WARNING! KEEP ALL COMBUSTIBLE MATERIALS AT LEAST
3.3'/1M FROM THE FRONT OF THE ELECTRIC FIREPLACE.
16
SERVICING REQUIREMENTS
DURING SERVICING OF THIS APPLIANCE IT MAY
BE NECESSARY TO CUT CABLE TIES IN ORDER TO
ACCESS AND REMOVE SOME OF THE PARTS.
THESE MUST BE REPLACED WHEN REASSEMBLING
THE APPLIANCE.
THIS APPLIANCE MUST ONLY BE SERVICED BY A SUITABLY
QUALIFIED PERSON.
BEFORE UNDERTAKING ANY WORK ON THE APPLIANCE:
SWITCH OFF THE APPLIANCE AND ISOLATE THE POWER
SUPPLY ENSURING THERE IS NO POWER TO THE APPLIANCE.
Wait for at least 10 minutes until the appliance has cooled down.
Remote Handset Battery Replacement
Replace with 2 AAA batteries. Make sure the batteries are installed
correctly in the remote control.
NOTE: The remote control has a Battery Status
indicator (top right corner), after an extended
period of displaying empty the LED screen will
cease to function despite the handset still being
able to send commands.
Replace the batteries to restore display.
Maintenance of Motors
The motor used on the flame effect is pre-lubricated for extended
bearing life and requires no further lubrication. However, periodic
cleaning/vacuuming of the heater unit is recommended.
Resetting the Thermal Cutout Switch
The appliance is fitted with an Electronic Safety Control (E.S.). This
is a safety device which switches off the fire if, the appliance
overheats for any reason e.g. when covered.
If the heater stops operating while the flame effect continues
normally, this indicates that the E.S. Control is in operation.
The E.S. Control can only be re-set after the appliance has cooled
down.
To re-set the E.S:
Switch off the appliance (Manual On/Off switch) and leave for
approximately 120 minutes.
Remove any obstruction to the fan heater outlet or other internal
parts.
Switch on appliance and the E.S. Control will re-set. Ensure that the
appliance is functioning correctly. If the E.S. Control operates again,
the appliance should be checked by a competent Electrician.

Advertisement