POWER CORD CONVERSION
IMPORTANT: A 15 AMP, 60Hz circuit is required for 120 VAC
installation. Additional appliances on the same circuit may
exceed the current rating of that circuit. A dedicated circuit is
not required but is preferred to prevent circuit breaker trips.
Locate the power supply which will be located on the right-hand
1
side if facing the front of the appliance. The location will vary
depending on model. It may be located at either the bottom or
top as shown below.
Bottom Location
Remove the wire harness & cover plate from the appliance
2
by removing the two Philip head screws from the side of the
appliance as shown below. Disconnect the Molex connector
and remove the wire harness & cover plate. Once removed
recycle or keep the wire harness & cover plate for future use.
Wire Harness
& Cover Plate
20
Top Location
Locate the 120 VAC power cord which will be in the manual
3
package that accompanied the appliance. Connect the 120 VAC
power cord option to the Molex connector on the appliance
(blue to blue, yellow to yellow, red to red).
Install the wire harness & cover plate and 120 VAC power
4
cord to the appliance and secure with the 2 x Philip head
screws removed in step 2.
Note: The appliance must be plugged into a 3 prong
5
receptacle which is exposed and accessible. Do not under any
circumstances, cut the ground on the 3-prong plug.
Wire Harness & Cover