Regency Fireplace Products P33-4 Owners & Installation Manual

Regency Fireplace Products P33-4 Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

Quick Links

Direct Vent Gas Fireplace
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-520
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
www.regency-fi re.com
P33-4 Zero Clearance
MODELS:
P33-NG4 Natural Gas
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
P33-LP4 Propane
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
6988 Venture St., Delta, BC Canada, V4G 1H4
Owners &
Installation Manual
06/08/06

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P33-4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Regency Fireplace Products P33-4

  • Page 1 P33-4 Zero Clearance Owners & Installation Manual Direct Vent Gas Fireplace MODELS: P33-NG4 Natural Gas P33-LP4 Propane WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fi...
  • Page 2 You are the owner of a state-of-the-art Gas Fireplace by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The P33-4 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
  • Page 3: Table Of Contents

    Optional Brick Panels ..........30 Log Set Installation ............30 Standard Flush Door ...........31 Optional Flush Trim .............31 Double Screen Door ............32 Optional Bay Door ............32 Optional Bay Trim ............32 Flush Louvers ..............32 Bay Louvers ..............33 ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 4: Safety Label

    SAFETY LABEL SAFETY LABEL This is a copy of the label that accompanies each P33-4 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open.
  • Page 5: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 6: Installation

    AND MAY CAUSE A SERIOUS 6) Venting terminals shall not be recessed into a 2) Ensure proper grounding using the #8 HOUSE FIRE. wall or siding. ground lug provided. Refer to "Wiring Diagram" Section. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 7: Installation Checklist

    INSTALLATION 4) The P33-4 can be installed in a recessed INSTALLATION UNIT DIMENSIONS position or framed out into the room as in CHECKLIST A, B, C, D. See Diagram 1 below. 5) This appliance is Listed for bedroom 1) Locate appliance...
  • Page 8: Combustible Mantels

    Combustible mantel leg clearances as per diagram below: Maximum 1-1/2" projection at 2" minimum clearance. The HeatWave Duct Kit has different clearance and framing requirements, Clearances for Bay or Flush Front check the HeatWave manual for details. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 9: Framing And Finishing

    HeatWave manual for details. You must maintain clearance from the vent to combustible materials for fl ex or for Rigid Vent (Refer to "Clearances" Section). ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 10: Unit Assembly Prior To Installation

    VENTING INTRODUCTION The P33-4 uses the "balanced fl ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
  • Page 11: Exterior Vent Termination Locations

    INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 12: Regency ® Direct Vent Fl Ex System

    Horizontal Terminations Only This venting system, in combination with the P33-4 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the "Exterior Vent Terminal Locations" Section .
  • Page 13: Installation Procedures

    2 x 4 or 2 x 6 walls. The liners must slip over the collars a minimum of 1-3/8". Wall Thimble 2 pieces (10" (254mm) Outer Diameter) ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 14: Rigid Pipe Venting Systems

    American Metal Products Ameri Vent Direct Vent, Security Secure Vent , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 15: Rigid Pipe Venting Components List

    Vent Guard (Optional) - Riser Vent Terminal 510-994 Rigid Pipe Adaptor (Must use with all Rigid Piping) 946-523/P AstroCap Horizontal Cap 640-530/P Riser Vent Terminal 946-206 Vinyl Siding Standoff - AstroCap ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 16: Rigid Pipe Venting Arrangements

    Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional rigid pipe adapter when using rigid vent systems (Part # 510-994). ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 17 INSTALLATION The P33-4 is approved for a maximum 40 ft. straight vertical, with rigid pipe vent systems for Propane and Natural Gas. The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas.
  • Page 18: Horizontal Terminations

    fi nal position. Also Rigid Vent venting cannot be used with any of the mantels noted above. See Price Pages for alternative options. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 19 3' Max. 4' Min. 6' Max. Please note minimum 4' Max. 6' Min. 7' Max. 1 foot between 90 elbows is required. 5' Max. 8' Min. 8' Max. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 20 1 foot between 90 required. elbows is required. 5' Min. 8' Max. 6' Min. 6' Max. 6' Min. For additional vertical venting with 2 x 90 elbows, refer to "Rigid Pipe Venting Arrangements" Section. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 21 5' Max. 7' Min. horizontal. 5' Min. 6' Max. 8' Min. Please note min. 1 foot 6' Min. 7' Max. 9' Min. between 90 elbows is required. 7' Min. 8' Max. 10' Min. Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 22: Vertical Termination With Co-Linear Flex System

    Air Intake that clearances to combustibles are maintained. Pipe Length Co-Linear Flex Rigid Pipe Adapter Adapter # 510-994 with Kit# 946-563 45 Elbow Inner Pipe Adapter with Kit# 946-563 Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 23: Venting Arrangements - Vertical Terminations

    VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 24: Unit Installation With Horizontal Termination

    Wall Note: Apply sealant "Mill-Pac" to inner Thimble (Part # 620-926) over the vent pipe and high temperature silicone sealant to outer pipe on every twist- pipe. lock joint. Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 25: Unit Installation With Vertical Termination

    fl ashing to the roof with roofi ng rails, detector. Do not use open fl ame for leak slide storm collar over the pipe section and testing. seal with a mastic. Diagram 2 ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 26: Pilot Adjustment

    2) Manual high/low adjustment 3) Pilot Adjustment 4) Thermocouple Connection - option 5) Outlet Pressure Tap 6) Inlet Pressure Tap 7) Pilot Outlet 8) Main Gas Outlet 9) Alternative TC Connection Point ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 27: Conversion Kit# 434-969 From Ng To Lp

    INSTALLATION CONVERSION KIT# 434-969 FROM NG TO LP For P33-4/H25-1 Using SIT 820 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! d) Remove the 2 screws holding the...
  • Page 28 10) Check that the screw is clean and if necessary remove dirt. 11) Flip the screw (Fig. 3). Fig. 6 WARNING! Also check that the pilot and main burner injectors are appropriate for the gas type. Fig.3 ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 29: Installation Of The Dc Sparker

    Connect the DC spark generator wires 15) Tie up the loose wire with the wire clip. to the SIT Valve with the screw, which is provided in the kit. Piezo Ignitor ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 30: Optional Brick Panels

    5) Slide the Top Brick Panel into position and slide the Top Brick Retaining clips so that they hold the Top Brick Panel in place and tighten down the screws. 2nd Grate Tab ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 31: Standard Flush Door

    Attach the round magnets to the back of the top trim piece and to the bottom trim piece, then attach trim to the top and bottom of Flush door. 5th Grate Tab ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 32: Double Screen Door

    fl ange of the fl ush door. 2) Secure to the fl ush door bottom bracket with 2 screws provided. Burner ON/OFF control box attached to bottom fl ush louver. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 33: Bay Louvers

    3) Install top louver by sliding the two bracket clips into the brackets located on top of the bay door. See below. The fi tted louver leaves a small gap between faceplate bottom and louver top. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 34: Full Screen Doors

    3) Before attaching the Full Screen Door Frame, remove the Screen Doors from the Full Screen Door Frame by fully opening the doors Cut-Outs and lifting up off of the hinges. See important note in step 10. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 35 7) Mount the Burner ON/OFF Control Box to the left side of the Bottom Grill using 2 x #8 - 1/4" Philips Head Screws. Left Side of Bottom Grill Screen Door Burner ON/OFF Control Box 11) Close screen doors. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 36: Optional Wall Thermostat

    The remote control is now ready for Thermostat (CP-2 System) operation. Wire Size Max. Length 14 GA. 50 Ft. 16 GA. 32 Ft. 18 GA. 20 Ft. 20 GA. 12 Ft. 22 GA. 9 Ft. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 37: Wiring Diagrams

    Piezo Ignitor (To THTP) White Burner ON Brown White (To TH) Thermostat Black To Thermocouple IN "S.I.T" Valve T-Stat ON OFF Remote Receiver Remote Transmitter or Thermostat (Optional) (Millivolt) (Optional) ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 38 Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 39: Installing The Optional Fan

    Push hold-down clip onto inside louver and press tab until it is at 90 to louver. Diagram 1 ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 40: Operating Instructions

    OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS Gas Inlet Gas Inlet ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 41: Operating Instructions

    After approximately one minute, This condensation is normal and will release the gas control knob. The pilot fl ame Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 42: Maintenance

    Log Installation. Note: Improper positioning of logs may create carbon build-up and will severely alter the unit's performance which is not covered under warranty. Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 43: Thermopile/Thermocouple

    Replacement of the glass panels should be done by a licensed or qualifi ed service person. Caution: Wear gloves when removing damaged or broken glass. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 44: Removing Valve

    17) Close the door and replace the louvers. 18) Fire up the unit again and check for proper fl ame appearance and glow on logs. Valve Tray Assembly screws Diagram 2: Rear Log Stand & Valve Tray Assembly Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 45: Parts List

    *Not available as a replacement part. 50) 904-713 U-Clip at Louver 31) * Flue Mounting Plate 432-967 Burner On/Off Switch Assy 63) 910-241 Switch - Burner On/Off 910-899 Wire Harness - Valve to Burner ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 46 PARTS LIST ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 47: Burner & Log Assembly

    Burner Grate Assembly - NG/LP 83) * Rear Log Support Bracket - NG/LP 85) 431-930 Log Set 86) 430-097 Air Defl ector-Left 87) 433-018 Air Defl ector-Right *Not available as a replacement part. Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 48: Flush Front & Louvers

    Screw - #8 x 1/2" 135) 940-088/P Glass (Flush) 137) 904-691 U-Clip ® 179) 948-216 Regency Logo Plate 139) 936-155 Glass Gasket (Tadpole) 140) 948-042 Spring Hinge - Black *Not available as a replacement part. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 49: Bay Front & Louvers

    Bay Louvers (set) - Steel/Black 125) * Bay Louver Assy-Top 433-026 Bay Door Defl ector 126) * Bay Louver Assy-Bottom 129) 948-042 Hinge 131) 948-216 Regency ® Logo Plate *Not available as a replacement part. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 50 NOTES __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 51: Warranty

    Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI. * Subsidy according to job scale as predetermined by FPI. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 52 Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency ® and Panorama are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved. ® Regency P33-4 Zero Clearance Direct Vent Gas Fireplace...

Table of Contents