Regency Fireplace Products Onyx EX110 Instructions For Use & Installation page 25

Led electric fire range with thermostatic remote control

Advertisement

NAILING FLANGES
NAILING FLANGES
Install nailing flanges as per diagram below. Phillips head
1
screw are provided to attach the nailing flange to appliance.
Slide unit into position.
2
INSTALLATION
EX110 x4
EX150 x6
EX190 x6
Secure appliance to framing as shown below with supplied
3
black wood screws.
PLUGGING POWER CORD TO APPLIANCE
PLUGGING POWER CORD TO APPLIANCE
The appliance is supplied with a 3 prong plug with a 72" lead which
is included with the manual package, it will need to be modified for
hard wiring.
Note: Must be plugged into a 3 prong receptacle which is exposed
and accessible. Do not under any circumstances, cut the ground on
the 3 prong plug.
This appliance is for use on 120 Volts only. The cord has a plug as
show in (A). An adapter as shown in (C) is available for connecting
three-blade grounding type plugs to two slot receptacles. The green
grounding lug extending from the adapter must be connected to
a permanent ground such as a properly grounded outlet box. The
adapter should not be used if a three-slot grounded receptacle is
not available.
Grounding Methods
Metal Screw
Cover of grounded
A
outlet box
Grounding Pin
To disconnect the appliance, turn the controls to off, then remove
plug from outlet.
This appliance must be connected and grounded in accordance with
1
local codes, if hard wired. In the absence of local codes, use the
current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the
current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United
State.
If appliance is to be hardwired, see this manual for details.
IMPORTANT: A 15 amp, 60Hz 120 Volt circuit is required for
installation of this Appliance. A dedicated circuit is not required, but
is highly recommended to prevent circuit breaker from tripping or
fuse failure. Failure to provide adequate power to this Appliance will
void your warranty.
B
Adapter - Not allowed in Canada
C
Grounding means