Regency Fireplace Products Energy E18E Owners & Installation Manual

Gas insert
Hide thumbs Also See for Energy E18E:
Table of Contents

Advertisement

Quick Links

Energy
f i r e - p a r t s . c o m
www.regency-fire.com
MODELS: E18E-NG11 Natural Gas E18E-LP11 Propane
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
Certified to/Certifié pour: CSA 2.17-2017
919-997a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
E18E Gas Insert
Installer: Please complete the details on the back cover and leave this
manual with the homeowner.
ANSI Z21.88-2017
CSA 2.33-2017
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
02.15.19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Energy E18E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Regency Fireplace Products Energy E18E

  • Page 1 Owners & Energy E18E Gas Insert ™ Installation Manual f i r e - p a r t s . c o m www.regency-fire.com MODELS: E18E-NG11 Natural Gas E18E-LP11 Propane WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
  • Page 2 CONGRATULATIONS! You are the owner of a state-of-the-art Gas Insert by: FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The Regency Gas Fireplace Series has been designed to provide you with all the warmth and charm ® of a fireplace, at the flick of a switch. The models E18E-NG and E18E-LP of this series have been approved by Intertek/Warnock Hersey for safety.
  • Page 3: Owner's Information U Nit Dimensions

    installation UNIT DIMENSIONS 34 7/16" 875mm 16 5/8" 423mm 11" 280mm 14 9/16" 370mm 3 15/16" 100mm f i r e - p a r t s . c o m 29 3/8" 747mm 23 9/16" 13 3/4" 598mm 349mm 23 15/16"...
  • Page 4: Table Of Contents

    table of contents owner's information Conversion Kit 617-977 - Natural Gas to Propane ....66 Glass Burner Installation / removal ........67 nit dimensions ...............3 Enamel panel Installation ............68 On Demand Pilot Light (seven day safety timer) .....5 Glass Crystals AND optional Ceramic spa or volcanic ..69 Before You Start ...............7 stones Installation On Burner and Firebox Floor ....69 Important Message ..............7...
  • Page 5: On Demand Pilot Light (Seven Day Safety Timer)

    safety decal This is a copy of the label that accompanies each Regency Gas Insert. We have ® printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit visible when the bottom louver is open. Duplicate Serial number Note: Regency units are constantly being improved.
  • Page 6 requirements MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 7: Before You Start

    owner's information BEFORE YOU START 2. The appliance when installed, must be electri- CLOTHING OR OTHER FLAMMABLE cally grounded in accordance with local codes, MATERIAL SHOULD NOT BE PLACED Safe installation and operation of this appliance or in the absence of local codes with the current ON OR NEAR THE APPLIANCE.
  • Page 8 owner's information 17. Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance. 18. The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids). 19.
  • Page 9: Lighting Procedure

    owner's information LIGHTING PROCEDURE IMPORTANT: The remote control system supplied with this appliance has 3. After approximately 4 seconds the spark ignition system will spark for 60 several options for starting/operating the appliance using the power button seconds to light the main burner. and ON/OFF key on the hand held transmitter.
  • Page 10: Copy Of Lighting Plate Instructions

    owner's information COPY OF LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 11: Proflame I Remote Control Operating Instructions

    owner's information PROFLAME I REMOTE CONTROL OPERATING INSTRUCTIONS PROFLAME I REMOTE CONTROL OPERATING INSTRUCTIONS IMPORTANT:The Proflame Transmitter 1 is an integrated part of the TECHNICAL DATA Proflame 1 System, which consists of these elements: • Proflame 1 Transmitter, to be used in conjunction with: REMOTE CONTROL •...
  • Page 12 owner's information Temperature indication Display Remote‑Flame Control With the system in the "OFF" position, press the Thermostat Key and The Proflame has six (6) flame levels. With the system on, and the flame the Mode Key at the same time. Look at the LCD screen on the transmit- level at the maximum in the appliance, pressing the Down Arrow Key ter to verify that a C or F is visible to the right of the room temperature once will reduce the flame height by one step until the flame is turned off.
  • Page 13 owner's information Smart Thermostat (Transmitter Operation) Remote dimmer control (Light)** The auxiliary function controls the AUX power outlet by the dimmable The Smart Thermostat function adjusts the flame height in accordance light control. To activate this function use the Mode Key (fig. 1) to index to the difference between the set point temperature and the actual room to the AUX icon (fig.
  • Page 14 owner's information LOW BATTERY POWER DETECTION Transmitter The life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the appliance, the number of changes to the room thermostat set point, etc. When the Transmitter batteries are low, a Battery Icon will appear on the LCD display of the Transmitter (Fig.
  • Page 15: Installer's Information

    requirements installer's information INSTALLATION GAS CONNECTION Specifications CHECKLIST Only persons licensed to work with gas piping For Altitude: Natural Gas 0-4500 ft. may make the necessary gas connections to this 1. Locate your appliance. Refer to the "Clearances Propane: 0-4500 ft. appliance.
  • Page 16: Pilot Adjustment

    installation PILOT ADJUSTMENT GAS PIPE PRESSURE HIGH ELEVATION TESTING This unit is approved in Canada for altitude to 4500 ft. (CAN/CGA-2.17-M91). For Natural Gas The appliance must be isolated from the gas Periodically check the pilot flames. Correct installations above 4500 ft. follow current CAN/ supply piping system by closing its individual flame pattern has two strong blue flames: CGA-B149.1.
  • Page 17: Installation Checklist

    installation NSTALLATION CHECKLIST MATERIALS REQUIRED The flue collar of the appliance will fit inside a standard vent and may be fastened directly to the vent using a minimum of 3 sheet metal screws or 1. Verify the model of the existing appliance you Electrical power supply is required for the circulation a B-Vent, single wall vent connector.
  • Page 18: Minimum Fireplace Clearances To Combustibles

    installation MINIMUM FIREPLACE CLEARANCES TO COMBUSTIBLES Diagram shows the minimum clearances to any combustible material. Installer must check that all installs maintain at least these clearances.. The minimum clearance from the side of the appliance to a combustible Note: A non-combustible mantel and framing may be installed side wall is 9"...
  • Page 19: Zero Clearance Framing Dimensions

    installation ZERO CLEARANCE FRAMING DIMENSIONS Framing Description E18E Dimensions Framing Height 36” (914mm) Framing Width 37 - 7/16" (951mm) Framing Depth 15-1/2" (394mm) Electrical connection: 110v required Fan must be on at all times to operate this unit. Note: All framing may be of wood construction.
  • Page 20: Zero Clearance Framing

    installation ZERO CLEARANCE FRAMING 1. Shut down existing unit and allow to cool to room temperature. 1. When installing the E18E as a zero clearance, you will use the framing clearances in the following diagrams. Mantel and inside corner clearances 2.
  • Page 21 installation 12. When framing is complete, ensure wiring is installed by an electrician 15. ZC surround installed into framed opening. prior to installing the unit. 16. Separate E18E inner and outer fireboxes - see installation into exist- 13. Assemble ZC surround with 8 (904-897) screws provided in locations ing unit section in the manual for details.
  • Page 22 installation 18. Follow instructions in the manual for installation into a EP28-2 for exact 21. Install lower trim piece with 2 (904-897) screws to the bottom of the measurements for installation of the outside firebox to the surround. ZC surround before installing faceplate. EP28 Installation Specifications EP28 Firebox 8 7/16"...
  • Page 23 installation REQUIRED STEPS AND PROCEDURES FOR E18E INSTALLATION Locate model on existing ZC box - locate corresponding section in this manual. Make necessary alteration to the ZC firebox as per manual. Separate inner and outer fire box (see procedure in manual). Remove flue adaptor for outer firebox.
  • Page 24: E18E-Separating The Outer Firebox Shell From Inner Firebox

    installation E18E SEPARATING THE OUTER FIREBOX SHELL FROM INNER FIREBOX 1. Lay fireplace insert on flat surface (use a drop sheet to protect surface). 2. Remove Glass Door by removing 2 x Phillips screws at the bottom of Glass Door Frame. 3.
  • Page 25: Modification Of Montigo Ep28-2, Ep28-4 Or Ep28-5

    installation MODIFICATION OF MONTIGO EP28-2, EP28-4 8. Remove hood and inner baffle (See Diagram 5.3). OR EP28-5 *Units could have any of the following Log Sets Installed: 2LB (2 Log Set), MB (2 Log Set), 4LB (4 Log Set) 1. Turn off unit, disconnect Gas and Power. 2.
  • Page 26: E18E Installation Specifications

    EP28 Firebox installation 8 7/16" 215mm E18E INSTALLATION SPECIFICATIONS See Installation of E18E into Existing Units for General Installation Guidance - for vent connection configuration. 1 7/16" 37mm 5 5/8" Vent Connection Type A This install of the E18E uses 143mm The length of 4"...
  • Page 27: Modification Of Montigo Ep28-S2

    installation MODIFICATION OF MONTIGO EP28-S2 5. Remove Front Bar (See Diagram 6.3). *S2 comes with a 6 piece Log Set. 1. Turn off unit and Disconnect Gas. 2. Remove Top and Bottom Louvers. 3. Remove Glass Door (See Diagram 6.1). Diagram 6.3 6.
  • Page 28 installation 8. Remove Efficiency Collar (See Diagram 6.6). 11. Bend Down the Three Flanges at the Bottom of the Firebox or Cut them Off (see Diagram 6.9). Diagram 6.6 9. Remove Fan (See Diagram 6.7). Diagram 6.9 Edges must be flush to allow proper seating of the E18E outerbox.
  • Page 29: Modification Of Montigoecono Plus 28C

    installation MODIFICATION OF MONTIGO 6. Remove heat deflector by removing 3 bolts and nuts. ECONO PLUS 28C 1. Turn off unit and Disconnect Gas. 2. Remove Top Louver Bars. 3. Remove Mesh Door Frame by removing 7 screws (See Diagram below). Remove 3 bolts and nuts to remove heat deflector.
  • Page 30 installation 10. Remove Serial No. Decal attached to valve assembly and affix to wall of 13. Cut to remove left and right cross piece at front of firebox. 28C firebox. Montigo Serial Decal Cut out front cross piece to remove 11.
  • Page 31 installation Completed modification 15. Prior to installing faceplate - use a #30 drill bit to remove upper trim / heat shield from outer faceplate. f i r e - p a r t s . c o m 16. Install outer faceplate to use as a template for measurements - ensure outer Faceplate is centered, mark and drill 2 holes per side.
  • Page 32: Montigo Econo Plus 28C Installation Specifications

    EP28 Installation Specifications EP28 Firebox installation 8 7/16" 215mm MONTIGO ECONO PLUS 28C INSTALLATION SPECIFICATIONS 1 7/16" E18E INSTALL SPECIFICATIONS 37mm 5 5/8" 143mm See Installation of E18E into Existing Units for General Installation Guidance for Vent Configuration. DETAIL A This install of the E18E uses Vent Connection Type A.
  • Page 33: Modification Of Montigo 28F-2 Or 28-F

    installation MODIFICATION OF MONTIGO 28F-2 OR 28-F 6. Disconnect Pilot Gas Line and Pilot Thermopile from the Valve. Disconnect Thermostat wires from valve. 1. Turn off unit, disconnect gas and power. 2. Remove Top and Bottom Louvers. 3. Remove Screen Mesh (See Diagram 7.1) or Bifold Doors. Diagram 7.3 7.
  • Page 34 installation 12. Bend Top Face Down (See Diagram 7.9). 9. Remove Sand Pan and Pilot Assembly. Diagram 7.9 13. Measure and draw a line 1" below the bottom of the exhaust collar (See Diagram 7.10). Diagram 7.6 10. Cut out the Bottom of the Firebox (See Diagram 7.7) f i r e - p a r t s .
  • Page 35 installation 15. Final Firebox Should Look Like Diagram 7.14. 14. Bend the Louver Mounts Flat. (See Diagram 7.13) Diagram 7.14 Diagram 7.13 Modified edges must be flush to allow proper seating of the E18E outerbox. f i r e - p a r t s . c o m Regency E18E-11 Gas Fireplace Insert ®...
  • Page 36: 28 F / 28 F2 Installation Specifications

    28-F / 28F-2 Firebox 7 3/16" installation 183mm 28 F / 28 F2 INSTALLATION SPECIFICATIONS 1 1/2" 6 1/16" 39mm 155mm E18E INSTALL SPECIFICATIONS DETAIL A Leg height setting SCALE 1 : 4 See Installation of E18E into Existing Units for General Installation Guidance for Vent Configuration. This install of the E18E uses Vent Connection Type A.
  • Page 37: Modification Of Montigo 28F-3

    installation MODIFICATION OF MONTIGO 28F-3 6. Disconnect valve from main burner Line (See Diagram 3). 1. Turn off unit, disconnect gas and power. 2. Remove Top and Bottom Louvers. 3. Remove Screen Mesh (See Diagram below) or Bifold Doors. Diagram 3 7.
  • Page 38 installation 8. Remove sand pan and pilot assembly. Diagram 8 Cut here to remove Diagram 5 11. Unscrew the top bar shown below. 9. Cut the plate located at the bottom of the firebox, as shown below. f i r e - p a r t s . c o m Diagram 6 Cut here to remove bar Diagram 9...
  • Page 39 installation 13. Unscrew the plate located between the 2 fixed bars, as shown below. Diagram 14 16. Remove the inside plate located at the rear of the cut plate. Diagram 11 14. Unscrew the plate locating underneath, as shown below. f i r e - p a r t s .
  • Page 40 installation 18. Bend top face down (See Diagrams 17 & 18). 20. Bend the Louver mounts until they lay flush. (See below) Diagram 17 Diagram 20 f i r e - p a r t s . c o m 21.
  • Page 41: 28F-3 Installation Specifications

    1 1/2" 6 1/16" 39mm installation 155mm DETAIL A Leg height setting SCALE 1 : 4 28F-3 INSTALLATION SPECIFICATIONS E18E INSTALL SPECIFICATIONS Leg Setting / Outer Shell Position See Installation of E18E into Existing Units for General Installation Guidance for Vent Configuration. This install of the E18E uses Vent Connection Type A.
  • Page 42: Modification Of Montigo 36Sr

    installation MODIFICATION OF MONTIGO 36SR 6. Remove Air Inlet Strip (See Diagram 8.3). *MUST USE FULL LENGTH LINER 4" 1. Turn off the unit and Disconnect Gas and Power. 2. Remove Top and Bottom Louvers. Diagram 8.3 f i r e - p a r t s . c o m Diagram 8.1 3.
  • Page 43 installation 8. Unscrew and Remove Trim Around Sand Pan (See Diagram 14. Unscrew the Bottom of the Firebox. (See Diagram 8.8) 8.5). 9. Disconnect Pilot Gas Line and Pilot Thermopile from Valve. 10. Disconnect Valve from Main Burner Gas Line. 11.
  • Page 44 installation 16. Remove Louver Supports in all 4 corners of the Appliance (See 17. Final firebox should look like Diagram 8.12. Diagram 8.11). Diagram 8.12 Diagram 8.11 Modified edges must be flush to allow proper seating of the E18E f i r e - p a r t s . c o m outerbox.
  • Page 45 36SR Firebox installation 6 3/8" 162mm E18E INSTALL SPECIFICATIONS 1 9/16" 40mm See Installation of E18E into Existing Units for General Installation Guidance. 6 15/16" 176mm This install of the E18E uses a full length 4" liner. DETAIL A Leg height setting SCALE 1 : 4 The Length of 4"...
  • Page 46 installation MODIFICATION OF FIRESONG 220N 4. Unscrew and Remove Front Inner Baffle (See Diagram 9.3). 1. Turn off and Disconnect Gas and Power. 2. Remove Valve Cover (See Diagram 9.1). Diagram 9.3 5. Cut the Sides of the Rear Inner Baffle at the Back of the Firebox (See Diagram 9.4).
  • Page 47 installation 8. Cut off support tab at the top of the firebox and final firebox 7. Cut The Top Front Flange of the Firebox (See Diagram 9.5). should look like Diagram 9.6. Diagram 9.6 Diagram 9.5 Modified edges must be flush to allow proper seating of the E18E outerbox.
  • Page 48: E18E Install Specifications

    8 3/16" 208mm installation E18E Install Specifications 5 1/4" 133mm See Installation of E18E into Existing Units for General Installation Guidance. This install of the E18E uses Vent Connection Type A. DETAIL C SCALE 1 : 4 Leg height setting The Length of 4"...
  • Page 49: Modification Of Firesong 120N

    installation 6. Unscrew and Remove Trim Around Sand Pan (See Diagram MODIFICATION OF FIRESONG 120N 10.4). 1. Turn off gas supply, if unit has a fan - turn off and disconnect power. 2. Remove Top Trim Pieces and Glass Doors- if installed (See Diagram 10.1).
  • Page 50 installation 11. Remove Top Front Flange of Firesong firebox. (See Diagram 10.8).Remove tabs on right and left side of firebox. 14. Cut out right side of existing Firesong firebox. (See Diagrams 10.11,10.12 and 10.13). Left and right cutout begins on front face - see Diagram 10.12 IMPORTANT: Cut out Firesong firebox and install support one side at a time.
  • Page 51 installation 18. Final modified firebox should look like Diagram 10.16 NOTE: Shown with flue collar and 6" length of flex installed. 15. Install supplied support section with 8 screws to reinforce Firesong firebox. (See Diagram 10.14). Firesong decal affixed Diagram 10.16 IMPORTANT NOTE: Separate inner and outer firebox on E18E (see instructions in this manual) Before installing outer firebox - lay on a flat surface and...
  • Page 52: E18E Installation Specifications

    EP28 Firebox installation 8 7/16" 215mm E18E INSTALLATION SPECIFICATIONS See Installation of E18E into Existing Units for General Installation Guidance - for vent connection configuration. 1 7/16" 37mm 5 5/8" The length of 4" Flex needed is 6" semi-expanded. 143mm Remove top flue adaptor from unit by removing 1 Philips screw and slide backward.
  • Page 53: Installation Of The E18E Into Existing Units

    installation INSTALLATION OF THE E18E INTO EXISTING UNITS STEP #1: VENT CONNECTION TYPE A Adaptor Plate Gasket 1. Attach the Flex Vent Section to the Adaptor Plate using 3 self drilling sheet metal screws. 2. Using 4 Sheet Metal Screws, attach the Adaptor Plate, Vent Section and Adaptor Plate Gasket to the top of the Adaptor Plate existing Fire Box.
  • Page 54: Step #2: Outer Shell Installation

    installation STEP #2: OUTER SHELL INSTALLATION Vent Slide Plate Existing Firebox attachement screw Vent Slide Plate 1. Slide outer shell back into the existing firebox, ensure the vent slide Step #2: plate is properly engaged with the outer shell. The E Move the outer shell back until the left and right flanges contact installed making it...
  • Page 55: Step #4: Surround Installation

    installation STEP #4: SURROUND INSTALLATION SURROUND INSTALLATION Run wire harness from unit through notch in mounting bracket ONLY TRIM KIT SUPPLIED BY THE MANUFACTURER SHALL BE and then to control box as shown below. USED IN THE INSTALLATION OF THIS APPLIANCE. Remove glass door and screen from unit by removing 2 screws.
  • Page 56 installation MONTIGO 28 F3 ONLY Attach front faceplate with 4 screws (2 on each mounting 12. To install fi ller piece, slide under faceplate and secure to bracket). (Touch up screws with black paint, after install.) backside of faceplate with magnets. Diagram 13.5 9.
  • Page 57: Zero Clearance Faceplate Installation

    E18E installation ZERO CLEARANCE FACEPLATE INSTALLATION ZERO CLEARANCE FACEPLATE INSTALLATION 1. Shut down existing unit and allow to cool to room temperature. ZERO CLEARANCE FRAMING DIMENSIONS 2. Turn off gas supply and disconnect electrical. Framing 3. Remove all accessories from existing unit, ie. glass doors, louvers, Description E18E etc.
  • Page 58 installation E18E ZERO CLEARANCE INSTALLATION ZERO CLEARANCE FRAMING When installing the E18E as a zero clearance, you will use the 1. When framing is complete, ensure wiring is installed by an electrician framing clearances in the following diagrams. Mantel and inside corner prior to installing the unit.
  • Page 59 E18E installation 4. ZC surround installed into framed opening. 7. Follow instructions in the manual for installation into a EP28-2 for exact measurements for installation of the outside fi rebox to the sur- round. Secure outer rebox to the ZC faceplate using 2 (904-897 )screws per side Secure with 2 screws...
  • Page 60 installation E18E FACEPLATE INSTALLATION Run wire harness from unit through notch in mounting bracket and then to control box as shown below. ONLY TRIM KIT SUPPLIED BY THE MANUFACTURER SHALL BE Notch in USED IN THE INSTALLATION OF THIS APPLIANCE. mounting bracket Remove glass door and screen from unit by removing 2 screws.
  • Page 61 E18E installation MONTIGO 28 F3 ONLY Attach front faceplate with 4 screws (2 on each mounting 12. To install fi ller piece, slide under faceplate and secure to bracket). (Touch up screws with black paint, after install.) backside of faceplate with magnets. Diagram 13.5 9.
  • Page 62: Optional Wall Thermostat

    installation Optional Optional Optional WALL THERMOSTAT REMOTE CONTROL WALL SWITCH Use the Regency Remote Control Kit approved 1. Run up to 10' of wire through the right or ® A wall thermostat may be installed if desired, for this unit. Use of other systems may void your left side gas inlet opening.
  • Page 63: Ac Power Adaptor Installation (For Surefire Systems)

    installation AC POWER ADAPTOR INSTALLATION (FOR SUREFIRE SYSTEMS) An AC power adaptor MUST be installed as a constant power source for the SureFire system. IMPORTANT: Do not use the 4-AA batteries in the SureFire receiver. INSTALL AC ADAPTOR WITH SUREFIRE WALL SWITCH/WALL THERMOSTAT ONLY - (WITHOUT REMOTE) 1.
  • Page 64: Gtm Remote Installation

    installation E18E GTM REMOTE INSTALLATION GTM REMOTE INSTALLATION 6. Remove the hi/lo knob if installed by removing 2 screws as 1. Shut off the gas supply and disconnect all power to the unit. shown below. 2. Remove the control cover. 3.
  • Page 65 E18E installation 10. To unattach these wires - un-clip from the wires on the stepper motor side as shown below. Press down this tab 11. Bundle all wires together and clip with supplied wire clip - as shown below. f i r e - p a r t s . c o m 12.
  • Page 66: Conversion Kit 617-977 - Natural Gas To Propane

    installation E18E Conversion from NG to LPG CONVERSION KIT 617-977 - NATURAL GAS TO PROPANE USING SIT 886 GAS VALVE for E18E using SIT 886 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 10. Reinstall new burner orifice LPG stamped Each Kit contains one LPG Remove pilot retainer clip with pliers and #55 and tighten...
  • Page 67: Glass Burner Installation / Removal

    installation GLASS BURNER INSTALLATION / REMOVAL 3. Screw down the Glass Burner with two screws. 1. Angle the Glass Burner up on left side and slide the mixing tube over the orifice. Diagram 14.3 f i r e - p a r t s . c o m Diagram 14.1 4.
  • Page 68: Enamel Panel Installation

    installation ENAMEL PANEL INSTALLATION ENAMEL PANEL INSTALLATION Black Enamel Panels • Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. •...
  • Page 69: Glass Crystals And Optional Ceramic Spa Or Volcanic

    installation GLASS CRYSTALS AND OPTIONAL CERAMIC SPA OR VOLCANIC STONES INSTALLATION ON BURNER AND FIREBOX FLOOR Evenly spread the Glass Crystals or optional Ceramic Spa Stones over the burner. Ensure the crystals (or stones) do not overlap too much as this will effect the flame pattern. IMPORTANT NOTE: Only the supplied approved Glass Crystals and Ceramic Spa Stones are to be used with these fireplaces.
  • Page 70: Brick Panel Installation

    installation BRICK PANEL INSTALLATION BRICK PANEL INSTALLATION 1. Position back brick panel on the back wall of the fi rebox. 5. Repeat steps 2-4 on other side. 2. Slide in side panel. Final Install f i r e - p a r t s . c o m 3.
  • Page 71: Log Tray Installation

    installation LOG SET INSTALLATION LOG TRAY INSTALLATION LOG SET INSTALLATION LOG TRAY INSTALLATION Installation of Panels must be completed before 1. Remove the Log Burner Tray from the box. Hang the front installing the log set. burner cover on the front edge of the burner tray. Place the Log * Log instructions shown with Black Enamel Panels Burner Tray on the Glass Burner Tray.
  • Page 72 installation 3. Place Log C at the front right of the log tray. 6. Place Log E on the right pin on Log A and on top of Log C. 4. Place ember lava, platinum embers, and embaglow on the burner, being careful not to cover the pilot or the gas ports.
  • Page 73: Optional Log Set Installation

    installation E18 - LOG INSTALLATION OPTIONAL LOG SET INSTALLATION Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.
  • Page 74 installation 9. Place Log piece (4 ) on the glass crystals in the location shown below. 12. Position Log 5, rest on pilot hood as shown below. 10" Right Log piece(4) positioned on glass 10. Install Log 3 by matching pin locator on Log 3 with right pin on Log Log 5 in position 1 as shown below.
  • Page 75: Glass Door / Screen

    installation GLASS DOOR / SCREEN INSTALLATION/ REMOVAL 1. Remove control cover to access door retainer screws. 2. Remove 2 door retainer screws. (Diagram 16.1) 3. Pull door out, then lift up and out to re- move. (Diagram 16.2) Door Retainers Screws (x2) 4.
  • Page 76: Drafthood Check

    installation DRAFTHOOD CHECK Check for proper draft by placing a match close The thermally actuated safety switch will auto- to the drafthood opening. This should be checked matically reset after it has cooled off. The switch will continue to cycle until the draft problem is after the unit has been operating for 15 min.
  • Page 77: Safety Switches

    installation SAFETY SWITCHES The E18E uses two safety switches to maintain proper operation. The first is a Spill Switch which will shut off the appliance if continuous spilling of exhaust gas from the drafthood occurs. The spill switch will shut off the Main Burner but not the Pilot.
  • Page 78: Copy Of The Lighting Plate Instructions

    operating instructions COPY OF THE LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 79: Operating Instructions

    operating instructions OPERATING AERATION INSTRUCTIONS ADJUSTMENT 1) Read and understand these instructions The air shutter can be adjusted by moving the before operating this appliance. adjusting wire up or down. The wire is accessed through the bottom louver opening. Open the air 2) Check to see that all wiring is correct and shutter for a blue flame or close for a yellower flame.
  • Page 80: Maintenance

    maintenance FIRST FIRE MAINTENANCE INSTRUCTIONS Burner Tray: The burner tray is positioned directly under the burner tube(s) and logs and is made of a different The first fire in your stove is part of the paint curing 1. Always turn the gas valve to off before cleaning. gauge material from the rest of the firebox and process.
  • Page 81: Log Replacement

    maintenance CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE. CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. LOG REPLACEMENT The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs.
  • Page 82: Valve Replacement

    maintenance INSTALLING VALVE VALVE REPLACEMENT 1. Place new valve tray and gasket into position. 1. Shut off the gas and electrical supply. 2. Reverse Steps 9-1. 2. Remove Faceplate Control Cover (see instructions in manual). 3. Check for gas leaks. 3.
  • Page 83: Removing The Fan

    maintenance REMOVING THE FAN IMPORTANT Disconnect power supply before servicing. 1. Shut off the gas and electrical supply. 2. Remove Control Cover. (see instructions in manual) 3. Remove Glass Door.(see instructions in manual) 4. Remove Log Set and Embers or crystals and stones (if installed). 5.
  • Page 84: Wiring Diagrams

    maintenance WIRING DIAGRAMS Caution: Ensure that the wires do This heater requires a 120V A.C. supply for codes the current CSA C22.1 (in Canada) or operation of the circulation fan which is required with the National Electrical Code ANSI/NFPA not touch any hot surfaces and are for operation of the fireplace.
  • Page 85: Wiring Diagrams

    maintenance WIRING DIAGRAMS (Do not cut the ground terminal off under any circumstances.) Fan must always operate with this unit. 911-265 f i r e - p a r t s . c o m Diagram 21.2 1. Remove wire labelled 911-240 in diagram above for GTM Remote and thermostat installation. 2.
  • Page 86: Main Assembly

    parts list MAIN ASSEMBLY 617-574/P Valve Assembly - NG 911-228/P Remote Receiver With Antenna Connect 0.584.525 617-776/P Valve Assembly - LP 911-210 External Antenna 911-004 Valve Only - NG 886 SIT IPI High/Low 0.886.002 918-835 Decal Logo Regency / Flame Sit Remote 911-005 Valve Only - LP 886 SIT IPI High/Low 0.886.003 918-875...
  • Page 87 parts list f i r e - p a r t s . c o m Diagram 22.1 Regency E18E-11 Gas Fireplace Insert ®...
  • Page 88 parts list EP28 Installation Kit f i r e - p a r t s . c o m Diagram 22.2 Part # Description Part # Description 616-070 Adaptor plate gasket E18E Body 616-069 Adaptor plate 616-068 Surround Panel Rear 904-960 Ring clamp -Installer supplied 616-067...
  • Page 89 parts list Montigo Econo Plus 28C Installation Kit EP28 Installation Kit f i r e - p a r t s . c o m Diagram 22.3 Part # Description Part # Description 616-070 Adaptor plate gasket E18E Body 616-069 Adaptor plate 616-049 Surround Panel Rear...
  • Page 90 parts list Montigo 28-F & 28F-2 Installation Kit f i r e - p a r t s . c o m Diagram 22.4 Part # Description Part # Description 616-070 Adaptor plate gasket E18E Body 616-069 Adaptor plate 616-068 Surround Panel Rear 616-067 Surround Panel Right...
  • Page 91 parts list Montigo 28-F3 Installation Kit f i r e - p a r t s . c o m Diagram 22.5 Item Part # Description Item Part # Description Faceplate panel Front Ring Clamp Magnet Bracket (not shown) Flex section Control Cover Adaptor Slide Plate E18E Chassis...
  • Page 92 parts list Montigo 36SR Installation Kit (Requires 4" liner) f i r e - p a r t s . c o m Diagram 21.5 Diagram 22.6 Item Part # Description Item Part # Description Surround panel Front Magnet Bracket (not shown) Control Cover Adaptor Slide Plate E18E Chassis...
  • Page 93 parts list Firesong 220N Installation Kit f i r e - p a r t s . c o m Diagram 22.7 Regency E18E-11 Gas Fireplace Insert ®...
  • Page 94 parts list Firesong 120N Installation Kit f i r e - p a r t s . c o m Diagram 22.8 Item Part # Description Item Part # Description Faceplate panel Front Ring Clamp Magnet Bracket (not shown) Flex section Control Cover Adaptor Slide Plate Firesong 120N Firebox supports...
  • Page 95 notes f i r e - p a r t s . c o m Regency E18E-11 Gas Fireplace Insert ®...
  • Page 96: Warranty

    warranty Limited Lifetime Warranty FPI Fireplace Products International Ltd. (for Canadian customers) and Fireplace Products U.S., Inc. (for U.S. customers) (collectively referred to herein as “FPI”) extends this Limited Lifetime Warranty to the original purchaser of this appliance provided the product remains in the original place of installation. The items covered by this limited warranty and the period of such coverage is set forth in the table below.
  • Page 97 warranty At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty. All warranty claims must be submitted by the dealer servicing the claim, including a copy of the Bill of Sale (proof of purchase by you).
  • Page 98 warranty Limitations of Liability: The original purchaser’s exclusive remedy under this warranty, and FPI’s sole obligation under this warranty, express or implied, in contract or in tort, shall be limited to replacement, repair, or refund, as outlined above. IN NO EVENT WILL FPI BE LIABLE UNDER THIS WARRANTY FOR ANY INCIDENTAL OR CONSEQUENTIAL COMMERCIAL DAMAGES OR DAMAGES TO PROPERTY.
  • Page 99 warranty Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 100 warranty f i r e - p a r t s . c o m 100 | Regency E18E-11 Gas Fireplace Insert ®...
  • Page 101 notes f i r e - p a r t s . c o m Regency E18E-11 Gas Fireplace Insert ®...
  • Page 102 notes f i r e - p a r t s . c o m 102 | Regency E18E-11 Gas Fireplace Insert ®...
  • Page 103 f i r e - p a r t s . c o m Regency E18E-11 Gas Fireplace Insert ®...
  • Page 104 f i r e - p a r t s . c o m Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Printed in Canada Regency and Energy are trademarks of FPI Fireplace Products International Ltd.

This manual is also suitable for:

E18e-ng11E18e-lp11

Table of Contents