Technosoft IDM240-5EI Technical Reference page 35

Table of Contents

Advertisement

12...48V
IDM240-5EI
+
12...48V
--------------------
12...80V
IDM640-8EI
Remark: The EARTH signal is connected internally to the metal case and to all SHIELD signals.
It is completely insulated from all electric signals of IDMx40. This feature may facilitate avoiding
ground loops. It is recommended that Earth be connected to GND at only one point, preferably
close to the V
supply output.
MOT
© Technosoft 2011
J2 - Motor & Supply Connector
V
MOT
To motor
J2
Earth
5
+V
MOT
6
+V
LOG
7
+
GND
8
Figure 3.7. J2 – Supplies connection
24
- Supplies Connection -
4-phase Inverter
Q5
Q3
Q1
Q7
Q6
Q4
Q2
Q8
Connected
to case
V
MOT
+3.3V
V
LOG
DC
GND
DC
IDMx40
IDMx40-xxI