Figure 2.12. De-rating with ambient temperature
Figure 2.14. De-rating with altitude
CAUTION!
17
I
– the nominal current
NOM
18
Stand-alone operation, vertical mounting
19
Fixed on metallic surface, vertical mounting. Temperature is measured at the contact area between the IDMx40 and the
heat sink.
© Technosoft 2011
17 18
Figure 2.13. De-rating with case temperature
Figure 2.15. Current De-rating with with PWM
For PWM frequencies less than 20kHz, correlate the
PWM frequency with the motor parameters in order to
avoid possible motor damage.
17
frequency
IDMx40 Technical Reference
19