2.5. Electrical Specifications

All parameters measured under the following conditions (unless otherwise noted):
T
= 0...40°C, V
amb
V
= 48 V
(IDM240-5EI) or 80 V
MOT
DC
Supplies start-up / shutdown sequence: -any- ;
Load current 5 A
RMS
Operating Conditions
1
Ambient temperature
2
Case temperature
Ambient humidity
3
Altitude / pressure
ESD capability
Storage Conditions
Ambient temperature
Ambient humidity
Altitude / pressure
ESD capability
1
Applicable to stand-alone operation; Operating temperature can be extended up to +80ºC with reduced current and
power ratings. See Figure 2.14 – De-rating with ambient temperature
2
Applicable when mounted on metallic surface; Operating temperature can be extended up to +80ºC with reduced current
and power ratings. See 2.15 – De-rating with case temperature
3
At altitudes over 1,000m, current and power rating are reduced due to thermal dissipation efficiency at higher altitudes.
See 2.16 – De-rating with altitude
© Technosoft 2011
= 24 V
, V
LOG
DC
24 VPLC
(IDM640-8EI);
DC
(IDM240-5EI) or 8 A
Mounted on metallic surface
Non-condensing
Altitude (referenced to sea level)
Ambient Pressure
Non-condensing
Altitude (referenced to sea level)
Ambient Pressure
Stand-alone
Original packaging
= 24 V
, CAN_V+ = 24 V
DC
(IDM640-8EI)
RMS
Min.
0.64
10
;
DC
Typ.
Max.
0
+40
0
+60
0
90
0 ÷ 1
+4
0.9 ÷ 1
4.0
-see electrical characteristics-
Min.
Typ.
Max.
-40
+85
0
100
0 ÷ 1
+4
0.9 ÷
0.64
4.0
1
±8
±15
IDMx40 Technical Reference
Units
ºC
ºC
%Rh
Km
atm
Units
ºC
%Rh
Km
atm
kV
kV

Advertisement