Technosoft IDM240-5EI Technical Reference page 26

Table of Contents

Advertisement

Analog Inputs
Differential voltage range
Common-mode voltage range
Input impedance
Common-mode impedance
Resolution
Diferential linearity
Offset error
Gain error
Bandwidth (-3dB)
RS-232
Standards compliance
Bit rate
ESD Protection
RS-485
Standards compliance
Recommended transmission line
impedance
Bit rate
Number of network nodes
ESD Protection
© Technosoft 2011
Referenced to GND
Differential, Tach input
Differential, Ref input
Referenced to GND; Tach input
Referenced to GND; Ref input
Common-mode voltage = 0...10 V
Common-mode voltage = 0...10 V
Ref input (depending on software settings)
Tach input
Depending on software settings
Human Body Model
Measured at 1MHz
Depending on software settings
Depending on software settings
Human Body Model
15
Min.
Typ.
Max.
±9.5
±10
±10.5
-12
0...10
+50
60
44
30
44
10
0.09
±0.1
±0.3
±0.5
±1
5
3.4
Min.
Typ.
Max.
TIA/EIA-232-C
9600
115200
±15
Min.
Typ.
Max.
TIA/EIA-485-C
90
120
150
11520
9600
0
64
±15
IDMx40 Technical Reference
Units
V
V
bits
2
% FS
2
% FS
2
% FS
kHz
kHz
Units
Baud
kV
Units
Ω
Baud
-
KV