Mitsubishi Electric MR-J4 B Series Instruction Manual page 54

General-purpose ac servo
Table of Contents

Advertisement

3. SIGNALS AND WIRING
3.3.3 Wiring CNP1, CNP2, and CNP3
Use the servo amplifier power supply connector for wiring CNP1, CNP2 and CNP3.
(1) Connectors
(a) MR-J4-10B to MR-J4-100B
Connector
Receptacle assembly
CNP1
06JFAT-SAXGDK-H7.5
CNP2
05JFAT-SAXGDK-H5.0
CNP3
03JFAT-SAXGDK-H7.5
(b) MR-J4-200B/MR-J4-350B
Connector
Receptacle assembly
CNP1
06JFAT-SAXGFK-XL
CNP3
03JFAT-SAXGFK-XL
CNP2
05JFAT-SAXGDK-H5.0
POINT
For the sizes of wires used for wiring, refer to section 11.11.
MR-J3-500B or more do not have these connectors.
Servo amplifier
CNP1
CNP2
CNP3
Table 3.1 Connector and applicable cable
Applicable cable
Size
AWG 18 to 14
MR-J4-200B
Servo amplifier
CNP1
CNP2
CNP3
Table 3.2 Connector and applicable cable
Applicable cable
Size
AWG 16 to 10
AWG 18 to 14
Insulator OD
3.9 mm or less
Insulator OD
4.7 mm or less
3.9 mm or less
3 - 13
Stripped
Open tool
length [mm]
9 mm
J-FAT-OT
MR-J4-350B
Servo amplifier
CNP1
CNP3
CNP2
CNP2
CNP3
Stripped
Open tool
length [mm]
11.5 mm
J-FAT-OT-EXL
9 mm
Manufa
cturer
JST
Manufa
cturer
JST

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melserivo-j4