1. FUNCTIONS AND CONFIGURATION
(3) MR-J4-500B
R S T
(Note 2)
( 2)
Power supply
Molded case circuit
breaker (MCCB)
(MCCB)
(Note 3)
( 3)
Magnetic
contactor
(MC)
(MC)
(Note 1)
( 1)
Line noise
filter
(FR-BLF)
L1
L2
L3
Power factor
improving DC
reactor
DC
(FR-HEL)
P+
Regenerative
option
C
Note 1.
The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
When not using the power factor improving DC reactor, short P3 and P4.
2.
Refer to section 1.3 for the power supply specification.
3.
Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that may cause the forced stop
deceleration to shift to the dynamic brake deceleration. When dynamic brake deceleration is not required, slow the time to turn
off the magnetic contactor.
L11
L21
P3
U
P4
V
W
CN5
CN3
CN8
CN1A
CN1B
CN2
CN4
Servo motor
1 - 17
Personal
computer
MR Configurator2
To safety relay or MR-J3-
MR-J3-D05
D05 safety logic unit
Servo system controller or
previous servo amplifier
CN1B
Next servo amplifier
CN1A or cap
Battery
Junction
terminal
block
CN1B
CN1A

Advertisement