11. Options and peripheral devices
(e) Radio noise filter (FR-BIF)
This filter is effective in suppressing noises radiated from the power supply side of the servo
amplifier especially in 10 MHz and lower radio frequency bands. The FR-BIF is designed for the
input only.
200 V class: FR-BIF
Connection diagram
Make the connection cables as short as possible. Grounding is
always required.
When using the FR-BIF with a single-phase power supply, always
insulate the wires that are not used for wiring.
MR-J4-350B or less
MCCB
MC
Power
supply
Radio noise
Mr-J4B-500B or more
MCCB
MC
Power
supply
Radio noise
Terminal
block
Servo amplifier
L1
L2
L3
filter
Servo amplifier
L1
L2
L3
filter
Red
White
Blue
29
58
11 - 45
Dimensions
Leakage current: 4 mA
Green
29
44
hole
7