5. PARAMETERS
No.
Symbol
PL17
LTSTS
Table 5.10 Load to motor mass ratio/load to motor inertia ratio
Setting value
PL18
IDLV
Magnetic pole detection - Minute position detection method - Identification signal amplitude
Set an identification signal amplitude used in the minute position detection method.
This parameter is enabled only when the magnetic pole detection is the minute position
detection method.
However, setting "0" will be 100% amplitude.
Name and function
Load to motor mass
ratio/load to motor
inertia ratio
0
10 times or less
1
10 times
2
20 times
3
30 times
4
40 times
5
50 times
6
60 times
7
70 times
Load to motor mass
Setting value
ratio/load to motor
inertia ratio
8
80 times
9
90 times
A
100 times
B
110 times
C
120 times
D
130 times
E
140 times
F
150 times or more
5 - 48
Initial
Setting
value
range
(unit)
Refer to Name
and function
column.
0