Mitsubishi Electric MR-J4 B Series Instruction Manual page 135

General-purpose ac servo
Table of Contents

Advertisement

5. PARAMETERS
No.
Symbol
COP9 Function selection C-9
PC27
This is used to select a polarity of the linear encoder or load-side encoder.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
COPB
PC29
Function Selection C-B
This is used to select the POL reflection at torque control.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PC31
RSUP1
Vertical axis freefall prevention compensation amount
Set the compensation amount of the vertical axis freefall prevention function.
Set it per servo motor rotation amount.
When a positive value is set, compensation is performed to the address increasing direction.
When a negative value is set, compensation is performed to the address decreasing direction.
The vertical axis freefall prevention function is performed when all of the following conditions
are met.
1) Position control mode
2) The value of the parameter is other than "0".
3) The forced stop deceleration function is enabled.
4) Alarm occurs or EM2 turns off when the (linear) servo motor speed is zero speed or less.
5) MBR (Electromagnetic brake interlock) was enabled in [Pr. PD07] to [Pr. PD09], and the
base circuit shut-off delay time was set in [Pr. PC16].
Name and function
Explanation
Selection of encoder pulse count polarity
0: Encoder pulse increasing direction in the servo motor CCW or
positive direction
1: Encoder pulse decreasing direction in the servo motor CCW or
positive direction
For manufacturer setting
Explanation
For manufacturer setting
POL reflection selection at torque control
0: Enabled
1: Disabled
5 - 38
Initial
Setting
value
range
(unit)
Refer to Name
and function
column.
Initial
value
0h
0h
0h
0h
Refer to Name
and function
column.
Initial
value
0h
0h
0h
0h
0
-25000
[0.0001
to
rev]/
25000
[0.01mm]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melserivo-j4

Table of Contents