Mitsubishi Electric MR-J4 B Series Instruction Manual page 225

General-purpose ac servo
Table of Contents

Advertisement

11. Options and peripheral devices
11.2.2 Selection of the regenerative option
(1) For rotary servo motor and direct drive motor
Use the following method when regeneration occurs continuously in vertical motion applications or when
it is desired to make an in-depth selection of the regenerative option.
(a) Regenerative energy calculation
From the calculation results in 1) to 8), find the absolute value (Es) of the sum total of negative
energies.
M
Friction
torque
T
F
T
U
Formulas for calculating torque and energy in operation
Regenerative
Torque applied to servo motor [N•m]
power
(J
+ J
) • V
L
M
T
=
1)
1
9.55 • 10
2)
T
= T
+ T
2
U
F
-(J
+ J
L
M
T
=
3)
3
9.55 • 10
4)
T
= T
4
U
(J
+ J
L
M
T
=
5)
5
9.55 • 10
6)
T
= -T
+ T
6
U
F
-(J
+ J
L
M
T
=
7)
7
9.55 • 10
11 - 8
Up
t
1
T
psa1
1)
(+)
(Power running)
2)
(Regenerative)
(-)
1
+ T
+ T
E
U
F
4
t
psa1
E
1
) • V
+ T
+ T
E
U
F
4
t
psa2
E
1
) • V
- T
+ T
E
U
F
4
t
psd2
E
1
) • V
- T
+ T
E
U
F
4
t
psd2
tf (1 cycle)
V
Time
Down
t
t
t
2
3
4
T
T
T
psd1
psa2
psd2
4)
8)
5)
6)
3)
7)
Energy E [J]
0.1047
=
• V • T
• t
1
1
psa1
2
= 0.1047 • V • T
• t
2
2
1
0.1047
=
• V • T
• t
3
3
psa2
2
= 0(No regeneration)
4
0.1047
=
• V • T
• t
5
5
psd2
2
= 0.1047 • V • T
• t
6
6
3
0.1047
=
• V • T
• t
7
7
psd2
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melserivo-j4

Table of Contents