Maintenance
• Turn OFF the power and ensure the safety before maintenance.
• Clean the lens with a lens-cleaning cloth or air brush.
• Lightly wipe off dirt with a soft cloth.
• Dirt on the image element must be removed using an air brush.
• Do not use thinners or benzene.
• To ensure safe access for operation and maintenance, separate the Sensor Controller as much as
possible from high-voltage equipment and power machinery.
Communication with High-order Device
• After confirming that this product is started up, communicate with the high-order device.
When this product has started up, an indefinite signal may be output from the high-order interface.
To avoid this problem, clear the receiving buffer of your device at initial operations.
Fail-Safe Measures
• When controlling stages and robots using the measurement results from the Sensor Controller (axis
movement output based on calibration and alignment measurement), always take fail-safe measures
within the stage and robot systems, such as checking whether the data obtained from the measure-
ment results is within the range of movement of the stages and robots.
• On a FH Sensor Controller side, supplementary use operations and branches of the FH Sensor Con-
troller to configure a check flow such as "data should not be externally provide if the data is in a range
from-XXXXX to XXXXX" based on the stage/robots range of movement.
Connecting the Sensor Controller and Monitor with a Switcher and
Splitter
• Do not use devices that may require re-recognition of the monitor by the sensor controller.
Re-recognizing the monitor during switch may slow.