Omron sysmac FH Series Hardware Setup Manual page 177

Vision sensor
Table of Contents

Advertisement

5-5-2
FH-1000/FH-3000 Series
Precautions for Safe Use
Ground
When the connected camera to the Sensor Control comes packaged with a base, make sure to
mount with the base.
Since the enclosure of the camera main body made of metals is short-circuited with the internal
circuit, the internal circuit might be short-circuited with FG if no base is used, so that failures or
malfunctions may be caused.
Connection the FH-1000/FH-3000 series to the FH-SC12/FH-SM12 (12 megapixels)
When you connect FH-1000 series or FH-3000 series to the FH-SC12/FH-SM12:
Do not ground the positive terminal of DC24V power source. The internal circuit is possible to
be given damage, it can be cause the failure.
Mounting of Ferrite core
Mount the ferrite core attached to the camera cable to near the Sensor Controller.
Camera cable mounting
When you connect the cable to the Sensor Controller, secure the minimum bending radius of the cable
or cable connector.
Connector length
Minimum
bending radius
Vision System FH/FZ5 series Hardware Setup Manual (Z366)
Name
Camera Cable
Right-angle Camera Cable
Bend resistant Camera Cable
Bend resistant Right-angle
Camera Cable
Long-distance Camera Cable
Long-distance Right-angle
Camera Cable
5 Setup and Wiring
Minimum
Connector
Model
bending
radius
FZ-VS3
69 mm
30 mm
FZ-VSL3
FZ-VSB3
FZ-VSLB3
FZ-VS4
78 mm
42 mm
FZ-VSL4
5
length
5 - 31