Built-In Installation (Continued)
If installing (Fig. 2-4):
i.
Built-In – No changes required.
ii.
2-Sided – Remove the side plate covering the side glass on the exposed side of the
fireplace. Install the drywall stop (shipped loose) on the exposed side of the fireplace. Store
the removed side plate and extra drywall stop in a safe place.
iii.
3-Sided/Bay – Remove the side plates covering the side glass on both sides of the fireplace.
Install the drywall stops (shipped loose) where the side plates were. Store the side plates in
a safe place.
Fig. 2-4
Hardwire the fireplace to the dedicated power circuit (see "Hardwiring Installation").
Install the fireplace in the framed opening. Adjust the adjustable feet as needed to ensure the
fireplace is level.
Fasten the fireplace to the framing using the "L" Metal Nailing Flanges and drywall screws that
have a minimum length of 1-1/4" (32mm) (Fig 2-5).
Mask the exposed viewing area of the fireplace prior to texturing/finalizing the framed wall.
Decorate according to media installation guide.
Install the front glass. See "Glass Removal/Installation."
Fig. 2-5