Lenovo ThinkSystem SD650 V3 User Manual page 93

Neptune dwc tray
Hide thumbs Also See for ThinkSystem SD650 V3:
Table of Contents

Advertisement

c.
Install the drive into the bottom of the drive cage and make sure it is secured in place.
Figure 65. Lower drive installation
3. Install the upper drive.
a.
Find the cable with its plugger marked as SSD 1/3, and connect it to the drive. Then,
pivot the drive into the top of the drive cage as shown.
b.
Push and hold the release latch.
c.
Slide the metal tab to the locked position.
Figure 66. Upper drive installation
After you finish
1. Install the drive cage. See
2. Install the cross braces. See
3. Install the tray cover. See
4. Install the tray into the enclosure. See
5. Connect all required external cables to the solution.
Note: Use extra force to connect QSFP cables to the solution.
6. Check the power LED on each node to make sure it changes from fast blink to slow blink to indicate all
nodes are ready to be powered on.
"Install a drive cage assembly" on page
"Install the cross braces" on page
"Install the tray cover" on page
"Install a DWC tray in the enclosure" on page
89.
47.
44.
.
Chapter 5
Hardware replacement procedures
42.
85