View Alarm; Setting Capacity Limit - Huawei LUNA2000-200KWH-2H1 Smart String ESS User Manual

Hide thumbs Also See for LUNA2000-200KWH-2H1 Smart String ESS:
Table of Contents

Advertisement

LUNA2000-200KWH-2H1 Smart String ESS
User Manual

10.7 View Alarm

Step 1 Check whether an alarm is generated on the SmartLogger WebUI or CMU WebUI.
If an alarm is generated, handle the alarm by referring to the handling
suggestions in the alarm reference section.
Step 2 Short-circuit the water sensor and check whether a water alarm is generated on
the SmartLogger WebUI or CMU WebUI:
After the alarm is cleared, choose Monitoring > Running Param. > Fire
suppression > Starting up on the SmartLogger WebUI or CMU WebUI.
Figure 10-26 Restoring the power supply
Step 3 Check whether an alarm is generated for the Smart Rack Controller on the
SmartLogger WebUI or CMU WebUI. If an alarm is generated, handle the alarm by
referring to the handling suggestions in the alarm reference section.
----End

10.8 Setting Capacity Limit

Context
Issue 02 (2023-02-28)
NO TE
● You are advised to use the SmartLogger WebUI.
● If Door Status Alarm is generated, check whether the cabinet door is open. If yes, close
the door.
● If ESU Communication Failure is generated, check whether communications cables are
connected correctly and whether the power supply is normal.
If a water alarm is generated, the water sensor is properly connected. In this
case, the water alarm will be cleared after the short circuit is removed.
If no water alarm is generated, check whether the water sensor cable is
connected properly.
Peak-valley arbitrage with capacity limit:
When the capacity limit is enabled in TOU mode, the charge/discharge time
set in the TOU window must cover 24 hours of a day. Capacity limitation is
not supported in non-charge/discharge time.
Capacity limit:
Copyright © Huawei Digital Power Technologies Co., Ltd.
10 SmartLogger Web-based Deployment
144