Installation
3.10.1 WD-B 500, electrically heated, one drying zone
3.10.2 WD-B 600, electrically heated, one drying zone
3.10.3 WD-B 700, electrically heated, one drying zone
3.10.4 WD-B 800, electrically heated, two drying zones
3.10.5 WD-B 900, electrically heated, two drying zones
•
Damper (I) half open.
•
Damper plate (B) fully open towards final rinse zone.
•
Spreader plate (E) pushed towards infeed. 2 mm gap between (E) and (D).
•
Guide plate 1 (D) pointed towards the outfeed and in its lower position.
•
Guide plate 2 (F) rotated through 180° (angled part upwards) and in its low-
er position.
•
Damper (I) half open.
•
Damper plate (B) fully open towards final rinse zone.
•
Spreader plate (E) pushed 15 mm from its central position towards the in-
feed.
•
Guide plates 1 and 2 (D, F) rotated through 180° (angled part upwards).
•
Damper (I) half open.
•
Damper plate (B) fully open towards final rinse zone.
•
Spreader plate (E) pushed 10 mm from its central position towards the in-
feed.
•
Guide plates 1 and 2 (D, F) fitted with the angled parts turned towards each
other.
•
Damper (I) half open.
•
Damper plate (B) fully open towards final rinse zone.
•
Drying zone 1: Spreader plate (E) in centre (gaps on both sides of equal
size). No guide plates (D, F) fitted.
•
Drying zone 2: Spreader plate (E) pushed towards the outfeed with a gap
between it and the outfeed of 10 mm. Guide plate 2 (F) pointed towards the
infeed (angled part towards the infeed) and in its lower position. No guide
plate 1 (D).
•
Damper (I) half open.
•
Damper plate (B) fully open towards final rinse zone.
•
Drying zone 1: Spreader plate (E) in centre (gaps on both sides of equal
size). No guide plates (D, F) fitted.
•
Drying zone 2: Spreader plate (E) pushed towards the outfeed with a gap
between it and the outfeed of 10 mm. Guide plate 2 (F) pointed towards the
infeed (angled part towards the infeed) and in its lower position. No guide
plate 1 (D).
WD-B 500 - WD-B 900
22
Rev. 4.0 (201208)