Service Sensor Transducer Block; Service Information Transducer - Endress+Hauser Levelflex FMP56 Operating Instructions Manual

Foundation fieldbus guided wave radar
Hide thumbs Also See for Levelflex FMP56:
Table of Contents

Advertisement

Levelflex FMP56, FMP57 FOUNDATION Fieldbus
Name
time_max_level
max_level_value
time_min_level
min_level_value
reset_min_max
interf_max_drain_speed
interf_max_fill_speed
time_max_interface
max_interface_value
time_min_interface
min_interface_value
application_parameter
operating_mode_ro
temperature_unit
activate_sw_option
target_echo_status
iface_target_echo_status
signal_noise_status
sens_temp_status
eop_shift_status
terminal_voltage_1
calculated_dc_value
upper_interface_thickness
debug_value
sw_option_active_overview
locking_status
decimal_places_menu_ro
linearization_type
eop_level_evaluation
access_status_tooling
calculated_dc_status
status_up_iface_thickness
debug_status
Endress+Hauser
Label
Time max. level
Max. level value
Time min. level
Min. level value
Reset min./max.
I max. drain speed
I max. fill speed
Time max. interface
Max. interface value
Time min. interface
Min. interface value
Application parameter
Operating mode
Temperature unit
Activate SW option
Status
Status
Status
Status
Status
Terminal voltage 1
Calculated DC value
Upper interface thickness
Debug value
SW option active overview
Locking status
Decimal places menu
Linearization type
EOP level evaluation
Access status tooling
Status
Customized upper phase thickness
status
9.6.7

Service Sensor Transducer Block

The parameters of the Service Sensor Transducer Block can only be operated by
authorized Endress+Hauser service personnel.
9.6.8
Service Information Transducer Block
The parameters of the Service Information Transducer Block can only be operated by
authorized Endress+Hauser service personnel.
Integration into a FOUNDATION Fieldbus network
Index Data type
Size (Bytes) Storage Class Write
84
STRING
85
FLOAT
4
86
STRING
87
FLOAT
4
94
ENUM16
2
88
FLOAT
4
89
FLOAT
4
90
STRING
91
FLOAT
4
92
STRING
93
FLOAT
4
95
ENUM16
2
108
ENUM16
2
72
ENUM16
2
110
UINT32
4
56
ENUM8
1
61
ENUM8
1
64
ENUM8
1
67
ENUM8
1
70
ENUM8
1
97
FLOAT
4
100
FLOAT
4
103
FLOAT
4
106
FLOAT
4
111
BIT_ENUM32 4
113
BIT_ENUM16 2
109
ENUM16
2
104
ENUM16
2
112
ENUM16
2
114
ENUM16
2
99
UINT8
1
102
UINT8
1
107
UINT8
1
MODE_BLK
access
Dynamic
Dynamic
x
AUTO
Dynamic
Dynamic
x
AUTO
Static
x
AUTO
Dynamic
x
AUTO
Dynamic
x
AUTO
Dynamic
Dynamic
x
AUTO
Dynamic
Dynamic
x
AUTO
Dynamic
Static
x
OOS
Static
x
AUTO
Static
x
AUTO
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
x
AUTO
Dynamic
Dynamic
x
AUTO
Static
Dynamic
Static
x
AUTO
Static
x
OOS
Static
x
OOS
Static
Dynamic
Dynamic
Dynamic
x
AUTO