Maintenance �� Syslog
Syslog Protocol
Syslog Server
Syslog Level
Syslog Keyword Filtering
Send SIP Log
Maintenance �� TR-069
ACS URL
TR-069 Username
TR-069 Password
Periodic Inform Enable
Periodic Inform Interval
Connection Request Username
Connection Request Password
Connection Request Port
CPE SSL Certificate
CPE SSL Private Key
If set to SSL/TLS, the Syslog messages will be sent through secured TLS protocol to
the Syslog server. The default setting is UDP.
Note: The CA certificate is required to connect with the TLS server.
URL or IP address of the syslog server for the GSC3570 to send syslog to.
Note: By adding a port number to the Syslog server field (i.e., 172.18.1.1:1000), the
GSC3570 will send Syslog to the corresponding port of that IP.
Selects the level of logging for syslog.
The default setting is "None".
There are 4 levels: DEBUG, INFO, WARNING and ERROR.
Syslog messages are sent based on the following events:
● Product model/version on boot up (INFO level).
● NAT related info (INFO level).
● Sent or received SIP message (DEBUG level).
● SIP message summary (INFO level).
● Inbound and outbound calls (INFO level).
● registration status change (INFO level).
● Negotiated codec (INFO level).
● Ethernet link up (INFO level).
● SLIC chip exception (WARNING and ERROR levels).
● Memory exception (ERROR level).
Syslog will be filtered based on keywords provided. If you enter multiple keywords, it
should be separated by ','.
Please note that no spaces are allowed.
Configures whether the SIP log will be included in the syslog messages. The default
setting is "No".
Note: By setting Send SIP Log to Yes, the GSC3570 will still send SIP log from syslog
even when Syslog Level set to NONE.
URL for TR-069 Auto Configuration Servers (ACS).
Default setting is: https://acs.gdms.cloud
ACS username for TR-069.
ACS password for TR-069.
Enables periodic inform. If set to "Yes", device will send inform packets to the ACS.
The default setting is "Yes".
Sets up the periodic inform interval to send the information packets to the ACS.
The default is 60sec.
The username for the ACS to connect to the phone.
The password for the ACS to connect to the phone.
The port for the ACS to connect to the phone.Defqult is 7547.
The Cert File for the phone to connect to the ACS via SSL.
The Cert Key for the phone to connect to the ACS via SSL.