On-Wall Mounting - Grandstream Networks GSC3570 User Manual

Hd intercom & facility control station
Hide thumbs Also See for GSC3570:
Table of Contents

Advertisement

3
4
5
6
7
8
9
10
J2
J3
J4
GSC3570 Setup
The GSC3570 can be attached to the wall or in-wall using the slots for wall mounting.

On-Wall Mounting

The GSC3570 can be mounted on the wall. Please refer to the following steps for Wall installation:
NC1
Green
IN+
White
GND
Black
AIN1
Blue
AIN2
Brown
AIN3
Gray
GND
Black
+12V
Red
Network Port
Micro SD Port
Data storage
Micro USB Port
Data exchange
Table 4: GSC3570 Wiring Connection
Figure 3: Built-in Stand and Mounting Slots on The GSC3570.
Alarm isolated input, for voltage
signal detection, IN+ connect the
sensor's signal output, please
Alarm IN (Active)
connect the GND to Alarm device's
GND or Negative of power. Active
voltage range 9-15V.
Voltage reference for IN+, Switch
Alarm GND
signal reference for AIN (1/2/3).
Alarm input, for button/door
Alarm IN
contacts switch signal detection.
Please connect the Switch/button to
(Passive)
AIN (1/2/3) and GND.
DC12V recommend, input voltage
Power Supply
rang 9-15V Current at least 1A at
12V.
Dual 10/100 Mbps Network ports:
POE Supply
One is POE port with class AF mode.
LAN Port
The other one is a LAN port.
Support microSD/SDHC/SDXC, up to
256G.
Data exchange port, Not
recommended to use this port to
power supply. If needed, please use
5V/2A adapter.