Bowers & Wilkins TECHNICAL SUPPORT
Note: Although it is possible to disassemble the Rear Isolator from the Drawbar it is
recommended that the Rear Isolator remains on the Draw Bar as removing the Draw Bolt
Fixing could damage the Draw Bar.
Once the Drawbar Assembly has been repaired or a replacement sourced refit in reverse
order.

15. 5" MF Cabinet Tube Removal

Start by removing the 8 x Hex Bolts shown in Figure: 33 and put these to one side for
reassembly.
Figure: 33
MF Cabinet Tube
Once all 8 x Hex Bolts have been removed the MF Cabinet Tube will fall forward as shown in
Figure: 34, take care not to damage the Gasket.
Figure: 34
MF Cabinet Tube
The contents of this document and associated files contain confidential information that is propriety to Bowers & Wilkins, and
are intended solely for the purpose of servicing the product. The information is intended for use by service technicians familiar
with electronic products. No part of the contents should be supplied or published elsewhere.
Page 30 of 51
8 x Hex Bolts
Note: Take care not to
drop any of the 8 x Hex
Bolts into the Cabinet or
scratch the MF Cabinet
Tube.
Note: Take care not to
Gasket
damage the Cabinet
when lifting the MF
Cabinet Tube away
from the Cabinet.
Also the Gasket may
stick to the MF Cabinet
Tube. Ensure that the
Gasket is in place as
shown in Figure: 35,
before refitting the MF
Cabinet Tube.