Bowers & Wilkins TECHNICAL SUPPORT
Figure: 16
HF Housing
HF Spade Terminal
To refit the replacement motor make sure the locating lug is in the correct orientation
and aligned with the receiver socket as shown in figure 17.
Figure: 17
HF Locating lug
Now carefully insert the replacement HF Motor back in to the HF Housing observing
the correction orientation. Using the HF Removal Tool rotate in a clockwise motion to
secure the motor in the HF Housing. Now replace the HF Tube and HF Rear Cap.
The contents of this document and associated files contain confidential information that is propriety to Bowers & Wilkins, and
are intended solely for the purpose of servicing the product. The information is intended for use by service technicians familiar
with electronic products. No part of the contents should be supplied or published elsewhere.
Page 20 of 51
HF Housing
Internal View
Thermal Pad
Tweeter
HF Motor
Assembly
HF Locating
lug receiver
HF Motor
Assembly
© Bowers & Wilkins 2016