Bowers & Wilkins 804 D3 Technical Manual page 24

Hide thumbs Also See for 804 D3:
Table of Contents

Advertisement

Bowers & Wilkins TECHNICAL SUPPORT
It will now be possible to carefully feed the Molex Crimp Pins through the HF Retaining Bolt,
the Molex Pins will only go through one at a time. The Tweeter Housing can now be lifted off
the Cabinet.as shown in Figure: 23.
Figure: 23
Tweeter Unit
HF Locating Pin Rear
Refit the replacement Tweeter Unit in reverse order and remember to tighten the HF
Retaining Nut with the HF Retaining Bolt Tool HH37842 shown in Figure: 24.
Figure: 24
And remember to refit the Molex Plug with the Black Lead fitted to the pointed side of the
Molex Plug as shown in Figure: 24
The contents of this document and associated files contain confidential information that is propriety to Bowers & Wilkins, and
are intended solely for the purpose of servicing the product. The information is intended for use by service technicians familiar
with electronic products. No part of the contents should be supplied or published elsewhere.
Page 24 of 51
HF front Locating Pin
HF Isolator
© Bowers & Wilkins 2016

Hide quick links: