Expansion

4.10 Power off

Turn external power source off.
Turn OFF the switch or relay between battery and inverter if available.
1) Operation
Press Start
LED out
Switch OFF
Reminding
Must close and lock the cover after operation
35 seconds for master battery to get system ready
(ensure all batteries online and external communication
working properly) The system still able to output power
during this 35 seconds.
During capacity expansion or replacement, when
parallel different SOC/voltage of module together, it is
recommended to maintain the system in idle
for >=15mins or till the SOC LEDs becomes similar
(<=1dot difference) before normal operation.
All the batteries LED will be out and stop showing any
status.
Press START button of master
battery module for more than 3
seconds until all LED on master
battery lighting, then release.
Swtich power switch of every
battery to OFF position.