Can And Rs485 Cable - Pylontech Pelio-L-5.12 Operation Manual

Lithium-ion phosphate battery
Hide thumbs Also See for Pelio-L-5.12:
Table of Contents

Advertisement

Reminding
Must sealing the terminal not used
3) Always remember to lock the terminal not used. The waterproofed locker is
connected on the LINK terminal at the beginning.
4.6.2

CAN and RS485 cable

1) Using the RJ45 cable from KIT W, KIT G, or outdoor network cable (CAT5E or higher
standard).
The RJ45 terminal of cable shall not have the sealing part.
Caution
Length of cable shall <=3 meters
2) Follow below process to fit the water-proof connector on to the RJ45 cable.
(The cable color blue in below picture is just for reference.)
Get ready
Put in
Finish on cable side
Connect to socket
1
Cross in the locker[1] first and then the sealing
rubber[2][3]
Put the RJ45 into the connector and then put in the
sealing rubbers
Rotate the locker[1] until the end
Then connect to CAN or RJ45 socket and then
2
3
4
rotate nut[4] to the end

Advertisement

Table of Contents
loading

Table of Contents