Procedure 10
Access the MICB remotely using a LAN hub – Succession 1000,
Succession 1000M Cabinet, and Meridian 1 Option 11C Cabinet
1
2
3
4
Procedure 11
Install MICB cards
1
2
3
4
5
6
7
Procedure 12
Set up CLI access from the Maintenance
1
2
553-3001-358
Standard 1.00
Insert the other end of the RJ11 plug into the RJ11 jack on the wall.
This procedure is now complete
Verify that the Ethernet Adapter/MAU is installed. Insert the industry-standard
MAU into the Ethernet Connection on the back of the Succession Call Server
and Succession Media Gateway.
Note: The MAU comes with the cable kits for the Succession Call Server and
Succession Media Gateway.
Insert the modular cable RJ-45 plug into the RJ-45 jack on the Ethernet
Adapter/MAU.
Insert the RJ-45 plug at the other end of the modular cable into the LAN hub.
Make the rest of the Ethernet connections as required using standard
Ethernet connection rules.
This procedure is now complete
Identify the card slots selected for MICB card(s). Refer to
Make sure to properly place the PCMCIA hard drive card in the lower
faceplate PCMCIA slot.
Pull the top and bottom extractors away from the MICB faceplate.
Insert the MICB card into the card guides and carefully push it until it makes
contact with the backplane connector.
Push the top and the bottom extractors towards the faceplate to insert the
MICB card into the faceplate connector and to lock it in place.
Observe the red LED at the top of the faceplate (the card LED).
This LED blinks three times after the self-test successfully completes. When
the MICB software loads, the LED blinks three more times and then remains
lit. This takes approximately 45 seconds.
Repeat Steps 1 through 6 for each additional MICB card.
This procedure is now complete
Specify the VT-100 type terminal interface characteristics to make sure they
are compatible with the MICB RS-232 interface.
Set the interface parameters as follows:
Transmission speed: 9600 bps
Data bits: 8
Stop bit: 1