Refer to Figure 27 when connecting the Maintenance terminal (that is,
VT100) in the following procedures.
Figure 27
Terminal connection through the Ethernet Adapter
Backplane
MICB Card
1
2
3
Indicate three ways of connecting the terminal.
Procedure 5
Access the MICB directly
1
2
3
4
Meridian Integrated Conference Bridge
I/O Panel
DB-9
RJ-45
Ethernet
Adapter
Backplane
Cable
Position the Maintenance terminal on a desk near the system.
Verify that the Ethernet Adapter card is on the I/O panel as described in
Procedure 4 on page
62.
Plug the terminal cable DB-9 female connector into the DB-9 male connector
on the Ethernet Adapter card on the I/O panel.
Plug the DB-25 male connector at the other end of the terminal cable into the
RS-232 connector on the terminal. A nullmodem is not required. If a gender
changer is required, purchase one from a local electronics store.
This procedure is now complete