Figure 9
Phantom TN definitions (LD 10
DES
TN
TYPE 500
CDEN 4D
CUST 0
WRLS NO
DN
AST
IAPG 0
HUNT
TGAR 1
LDN
NCOS 0
SGRP 0
RNPG 0
XLST
SCI
SCPW
SFLT NO
CAC
CLS
PLEV 02
AACS NO
MLWU_LANG
FTR
The next step is to configure MICB ports as digital sets.
Table 8
LD 11 – Configure MICB ports as digital sets. (Part 1 of 2)
Prompt
Response
REQ
NEW
TYPE
2616
TN
l s cu
c u
CUST
xx
Meridian Integrated Conference Bridge
MICB
xxx
x
xx
xx
xxxx
x
MARP
NO
NO
0
3
CTD
DTN
FBD
LPR
XRD
CWD
SWD
CFTD
SFD
MRD
C6D
ICDD
CDMD
LLCN
EHTD
GPUD
DPUD
CFXA
ARND
MBXD
CPFA
CPTA
HSPD
NRWD
NRCD
NROD
SPKD
EXRO
SHL
ABDD
CFHD
CWND
USRD
BNRD
OCHD
0
DCFW
12
<ACD
Description
Add new data.
Digital telephone set M2616.
Terminal number of the MICB card, for Large Systems.
For Succession 1000, Succession 1000M Cabinet, and
Meridian 1 Option 11C Cabinet.
Customer number.
)
PHANTOM
XFD
WTA
THFD
MWD
LPD
XHD
CNID
CLBD AUTU
MCTD
OVDD
AGTD CLTD
UDI
ACC
HBTD
CRD
PRSD MCRD
DNAA
RTDD
FAXD
DN>