Meetings Log Report - Nortel Meridian Meridian 1 Implementation Manual

Meridian integrated conference bridge
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

Page 168 of 208
Short port occupancy can indicate a fault condition on a port or can
indicate that a user is dialing the incorrect DN. Set the short occupancy
range in the System Attributes Editor menu, which can range from 0 to
30 seconds.
From the Short Connection Report menu, the option is available to print
(p) or reset (r) the counter to zero. When printing the short connection
peg-count, the system presents all ports with a count in the following
format:
The counts have the following meanings:
If all counters are zero, the system prints the header followed by the
message "all counters are zero".
Short Connection Report CLI example

Meetings Log Report

BUI Meetings Log Report
The BUI sorts the Meetings Log Report by DN. The BUI displays the
report with events grouped by meeting. Therefore, the window shows a
"Select DN" pull-down menu to enable the selection of the particular
DN's records to appear in the report.
the BUI displays the report, which has the same text lines that the CLI
prints when RGen/MLog is entered. The BUI adjusts the font to make
this report easier to read.
If the report does not fit on one window, click on the Next Page button
to display more information.
553-3001-358
Standard 1.00
port #
today's_count
today's count – count of short connections that occur this day.
total count – cumulative count of all short connections since the
MICB was last reset, or the system reset the short connection
counters.
STest, MReport, SCon, ARchivdb, REstordb, CRestart, ?: sc
Print, Reset: p
Port #
today's_count
10
2
18
1
31
5
Print, Reset: r
Reset all short connection counters? (Yes, (No)) Yes
Counters reset.
Print, Reset: *
STest, MReport, SCon, ARchivdb, REstordb, CRestart, ?:
October 2003
total_count
total_count
4
10
34
Figure 72 on page 169