Table 9
LD 23 – Configure the main DN for dual-card conferences. (Part 2 of 2)
Prompt
Response
Note:
Carriage return to the end and start again.
REQ
NEW
TYPE
NACD
CUST
xx
ACDN
xxxx
TABL
N
- TRGT
xxxx 0
- TRGT
yyyy 2
Table 10 shows a sample dialing plan for a 62-port dual-card
configuration.
Table 10
Sample dialing plan for a 62-port dual-card configuration
Description of DNs
ACD DN
Pair DNs for single-
card conferences
TUI DNs
Chairperson DNs
Transfer DN
Link DN
Main DN
553-3001-358
Standard 1.00
Description
New control data block.
Network ACD data block.
Customer number.
The main DN for dual-card conferences.
Night time overflow table.
xxxx is the ACD DN of the primary card.
0 is the time, in seconds, for an immediate transfer to the
primary card.
yyyy is the ACD DN of the secondary card.
2 is the time, in seconds, for a delayed transfer to the secondary
card.
DNs for the
primary card
7000
7001-7018
(NCFW = 7000 in
LD 23)
7019 (NCFW = 7000)
7020 (NCFW = 7000)
N/A
N/A
7021(TRGT = 7000 0)
October 2003
DNs for the
secondary card
8000
8001-8018
(NCFW = 8000 in
LD 23)
8019 (NCFW = 8000)
8021 (NCFW = 8000)
8022 (NCFW = 8000)
7021 (TRGT = 8000 2)
Configure in...
LD 23
LD 23
LD 23
LD 23
LD 23
LD 23
LD 23