Calibrating Barometric
Pressure Readings
The watch's pressure sensor is adjusted at the
factory and normally does not require
calibration. However, you can calibrate the
displayed value if you notice major errors in
readings.
Important!
The watch will not be able to produce
correct barometric pressure readings if
you make a mistake during the
calibration procedure. Check to make
sure that the value you use for
calibration produces correct pressure
readings.
1.
Display the current time screen.
Watch Mode
l
2.
Use (A) and (D) to select [BAROMETER].
3.
Press (C).
This displays the current barometric
pressure and temperature.
4.
Hold down (A) for at least two seconds.
This displays the barometer/temperature
measurement setting screen.
Pointer
Watch Operation Guide 3515
5.
Use (A) and (D) to move the pointer to
[BAROMETER CALIBRATION].
6.
Press (C).
7.
Use (A) and (D) to move the pointer to
[MANUAL].
Selecting [OFFSET OFF] returns
barometric pressure calibration to its
factory default state.
8.
Press (C).
This displays the manual correction
screen.
9.
Use (A) and (D) to input the current
barometric pressure.
10.
Press (C) to complete the setting
operation.
After the setting operation is complete, a
check mark appears for a few seconds,
and then the barometric pressure/
temperature setting screen re-appears.
11.
Press (E) to exit the setting screen.
Calibrating Temperature
Readings
The watch's temperature sensor is adjusted at
the factory and normally does not require
calibration. However, you can calibrate the
displayed value if you notice major errors in
readings.
Important!
Check to make sure that the value you
use for calibration produces correct
temperature readings.
Before calibrating the temperature
reading, remove the watch from your
wrist and leave it in the area where you
plan to measure temperature for about
20 or 30 minutes to allow the case
temperature to become the same as
the air temperature.
1.
Display the current time screen.
Watch Mode
l
2.
Use (A) and (D) to select [BAROMETER].
3.
Press (C).
This displays the current barometric
pressure and temperature.
4.
Hold down (A) for at least two seconds.
This displays the barometer/temperature
measurement setting screen.
Pointer
5.
Use (A) and (D) to move the pointer to
[THERMOMETER CALIBRATION].
6.
Press (C).
49