Suppress Leading Zeroes; Loop-Back Self-Test; Cpu Board Part Number; Indicator Type/Serial Format - Rice Lake SURVIVOR IQ F Series Installation Manual

Flip digit remote displays
Table of Contents

Advertisement

3.2.7

Suppress Leading Zeroes

Switch DSW3-6 enables suppression of leading
zeroes in weight values of less than 1. If DSW3-6 is
set on, weight values of less than 1 are shown with
only one zero to the left of the decimal point. For
example, a weight value received as 000.432 is shown
as 0.432.
If DSW3-6 is set off, the remote display shows the
zero format as sent by the indicator.
3.2.8

Loop-Back Self-Test

Switch DSW3-7 enables the loop-back self-test used
to check the remote display serial port. For normal
operation, set this switch off. See Section 5.3 on
page 14 for information about using the loop-back
self-test.
3.2.9

CPU Board Part Number

DSW3-8 specifies the part number of the CPU board
installed in the remote display. Some early production
units use CPU board PN 41033. The CPU board part
number is printed on the CPU board, slightly above
and to the right of DIP switch DSW4.
3.2.10

Indicator Type/Serial Format

Table 3-5 on page 8 shows the DSW4 switches used
to identify the serial format sent by the attached
indicator unless learn mode is used (see Section 3.2.4
on page 5). If learn mode is enabled, the DSW4
switch settings are ignored.
Learn mode may be unable to read the serial
NOTE:
strings sent by some indicators or particular indicator
configurations. If learn mode is unable to interpret the
serial string, set switch DSW2-8 off and use Table 3-5
to set DSW4 for the attached indicator.
3.3
Setting the Clock (for Units with the
Time Option Installed)
Once remote display configuration is complete and the
unit powered on, set the clock by doing the following:
1. Turn the clock switch to the
to set the hour. Hours digits count up once per
second while the switch is held in the
position. Release the switch when the
SET
current hour is displayed.
2. Turn the clock switch to the
to set the minute. Minutes digits count up
once per second while the switch is held in the
position. Release the switch when
MIN SET
the current minute is displayed.
The clock chip contains its own battery which
maintains the current time when the remote display is
powered off.
The current time is displayed when the weight reading
received by the remote display is zero. If the
temperature option is also installed and enabled, the
time and temperature displays alternate.
position
HRS SET
HRS
position
MIN SET
Configuration