Power supply
Specification
Intake reduction
Lambda probe heating
Front injector
Rear injector
Front coil
Rear coil
Errors display screen page

ERRORS DISPLAY

This screen page shows potential errors detected
in the vehicle (ATT) or stored in the control unit
(MEM) and it allows to check error clearing (STO).
Specification
High atmospheric pressure sensor
Air temperature sensor
Low air temperature sensor
High air temperature sensor
Water temperature sensor
Low water temperature sensor
High water temperature sensor
Low throttle sensor
High throttle sensor
Lambda probe
P SUPP - 210
Fan
ERRORS DISPLAY
TUONO R_FACTORY
Desc./Quantity
There is no movable flap on this vehicle, therefore this activa-
tion is unnecessary.
The device is activated: if it is not correctly activated, NO is
displayed immediately, which shows that it has not been acti-
vated, but it is also necessary to check the errors display screen
page
The device is activated: if it is not correctly activated, NO is
displayed immediately, which shows that it has not been acti-
vated, but it is also necessary to check the errors display screen
page
The device is activated: if it is not correctly activated, NO is
displayed immediately, which shows that it has not been acti-
vated, but it is also necessary to check the errors display screen
page
The device is activated: if it is not correctly activated, NO is
displayed immediately, which shows that it has not been acti-
vated, but it is also necessary to check the errors display screen
page
The device is activated: if it is not correctly activated, NO is
displayed immediately, which shows that it has not been acti-
vated, but it is also necessary to check the errors display screen
page
The device is activated: if it is not correctly activated, NO is
displayed immediately, which shows that it has not been acti-
vated, but it is also necessary to check the errors display screen
page
Desc./Quantity
Displayed in case of excessive voltage detected on the sensor
circuit
Displayed in case of low voltage detected on the sensor circuit
Displayed in case of excessive voltage (for example interrupted
circuit, in the frozen parameters, but it reads -40° maximum
ohm resistance)
Displayed in case of low voltage detected on the sensor circuit
Displayed in case of excessive voltage (for example interrupted
circuit, in the frozen parameters, but it reads -40° maximum
ohm resistance)
Displayed in case of low voltage detected on the sensor circuit
Displayed in case of low or null voltage (for instance interrupted
circuit)
Displayed if the probe signal circuit is interrupted or has prob-
lems during the probe operating phase, turns to STO without
reconnection, and thus is not saved to the memory: it also no-
-
-

Hide quick links: